The Anthropometric Equipment range covers the scales, boards and tapes used to measure body weight, length or height and mid-upper arm circumference in growth monitoring and nutrition surveys, with child ID bracelets for the same sessions. Clinics, health centres, field survey teams and nursing, nutrition and public-health training courses use them. All items in this range are supplied by ScienceLab, Ambala.
| Group | What it covers | Example products |
|---|---|---|
| Hanging spring scales and accessories | Tubular and dial-faced spring scales for infants and young children, with a square weighing sling for babies and weighing trousers for toddlers. | Scale, Infant, Spring Type, 5kg x 25g, Scale, Infant, Spring Type, 25kg x 100g, Weighing Trousers |
| Infant and child scales | A beam scale with a curved tray for babies lying down, an electronic baby scale with TARE and HOLD, and a child scale that comes with a height tape and washable sheet. | Scale, Infant, Clinic, Beam Type, 16kg x 10g, Electronic Scale Baby, Scale for Children with Height Tape |
| Adult and mother-child scales | A floor-standing physician beam scale, an electronic floor scale with a mother-child mode on mains, solar or battery power, and a column scale with height rod that calculates BMI. | Scale, Physician, Adult, Metric, 6-180kg, Scale Mother/Child Batteries Mains Solar, Scale for Adults with Height Rod |
| Length and height boards | Folding boards that measure babies lying down and children standing, one of them with extensions for measuring adults. | Portable Baby/Child L-hgt, Portable Baby/Chd/adult L-H |
| MUAC tapes and ID bracelets | A colour-banded child MUAC tape, a plain graduated adult tape, and red and blue single-use, tamper-proof child ID bracelets. | MUAC, Child 11.5 Red, MUAC, Adult, Without Color Code, ID Bracelet, Child, Red |
Choose the equipment by who is measured and where. Field teams visiting homes often carry a dial spring scale with a sling or weighing trousers and a folding length board, since none of these needs power. A fixed clinic can use the beam-type infant scale or the Electronic Scale Baby for babies, and a floor or column scale for older children and adults.
Set each floor scale on a firm, level floor and each baby scale on a firm, level table, or hang a spring scale from a secure hook at eye level. Re-zero for each child, with the empty sling, trousers or liner already on the scale. Weigh babies undressed or in a dry nappy, read the scale only when the pointer or display is still, and write the figure down at once. After the session, fold the length boards, pack tapes flat and store everything clean and dry, away from heat.
A set usually covers four tasks: weight, length or height, arm circumference and identification. From this range that means spring or electronic scales with a sling or weighing trousers, a folding length board, MUAC tapes and child ID bracelets. The Portable Baby/Chd/adult L-H and the mother-child floor scale let one set serve children and adults alike.
Choose by the tallest person the team will measure. A child clinic that sees only babies and young children can work with the Portable Baby/Child L-hgt, which stops at 120 cm. A household survey that also measures older children and adults needs the Portable Baby/Chd/adult L-H, whose two extensions carry it to 204 cm. Either board measures lying length and standing height in 0.1 cm steps.
Two in this range. The Scale for Children with Height Tape comes with a height tape meter and a washable sheet, so a child's length or height is noted with the weight. The Scale for Adults with Height Rod lists a height rod as available with the scale. The spring and beam scales weigh only, so teams pair them with one of the length boards.
Wipe trays, boards and scale platforms with a damp cloth and mild detergent between children, and let them dry before the next one. The washable sheet supplied with the Scale for Children with Height Tape can be laundered, and slings and weighing trousers need regular washing. The ID bracelets are single use, so each one is fitted to one child only.
The MUAC, Child 11.5 Red has red, yellow and green bands, so a community worker can record which band a child's arm reading falls in, and it is also graduated in 1 mm steps. The MUAC, Adult, Without Color Code has no bands and gives the reading in millimetres, for staff who work to their own protocol.
The spring scales, such as the 5 kg tubular infant scale, and the beam scales, the infant clinic scale and the adult physician scale, are mechanical and need no batteries or mains. The Electronic Scale Baby runs on mains or replaceable batteries, and the mother-child floor scale on mains, direct solar power or AA batteries.
A growth-monitoring session often measures more than the arm, so the Tape Measure Fibreglass Tailors is supplied for other body circumferences and the Bathroom Scales for school health lessons. Buyers in 110 countries, from training colleges to dealers, take these scales, boards and tapes from ScienceLab, a Jain Scientific Equipments Pvt Ltd business based in Ambala, Haryana. See the ScienceLab company profile.
To request a quotation or a catalogue for this range, send the product names, codes and quantities through our contact page or add the items to your enquiry cart.
Last updated: 15 November 2026
This square fabric sling carries a newborn or young infant on a hanging spring scale. The 80 x 80 cm panel holds a baby of up to 5 kg lying flat, for ages 0 to 6 months. Two straps, each fixed at two parallel corners, go over the scale's lower hook, and the double-stitched, non-elastic fabric is machine washable.
| Parameter | Detail |
|---|---|
| Type | One-size-fits-all weighing sling for spring scales |
| Intended users and load | Newborns and infants aged 0–6 months; holds an infant up to 5 kg |
| Shape and size | Square, 80 x 80 cm (±5%) |
| Suspension | 2 straps/handles; each strap fitted with both ends on 2 parallel corners of the sling |
| Strap length | 40 cm (±10%) |
| Fabric and seams | Soft and flexible but non-elastic, easy to clean; double-stitched seams |
| Washing and shrinkage | Machine washable up to 40°C with domestic-type detergent; shrinks not more than 10% after such washing |
| Product code | SLE/AE/01 |
| Minimum order | 10 units |
| Dispatch | Usually within 7 to 10 working days |
| Supplied by | ScienceLab (Jain Scientific Equipments Pvt Ltd), Ambala, India |
Setting up a newborn weighing station. Hang the 5 kg tubular spring scale from a beam or tripod and pass both sling straps over its lower hook. Check that neither strap is twisted and that the square panel hangs level, then zero the scale with the empty sling before the first baby arrives.
Tare practice for trainees. Each trainee weighs the empty sling and writes the figure down. The group then weighs one baby twice: once with the scale zeroed on the empty sling, and once without zeroing, taking the sling weight away from the reading. The two results should agree, and any gap points to a reading or arithmetic slip.
Moving up a size. At every visit, note whether the baby can sit and how close the weight is to 5 kg. A baby who sits, or who nears that limit, moves to weighing trousers on the 25 kg dial spring scale. Length is taken on a portable baby and child length board during the same visit.
Any hanging spring scale with a lower hook that covers the baby's weight. Pass both straps over the hook so the panel hangs level. The 5 kg x 25 g tubular infant scale is a good match, because its range ends at the same 5 kg limit as the sling.
Open the panel flat, lay the undressed baby on its back in the centre and let the fabric close around the body. Keep your hands close but not touching while you read. A baby lying off-centre tilts the sling, and the pointer then swings for longer.
Machine wash it at no more than 40°C with an ordinary domestic detergent, then dry it fully before the next session. Washed this way, the fabric shrinks by no more than 10%. Clinics that weigh many babies keep a second sling, so one is always clean and dry.
Stretchy cloth would let the baby bounce, so the pointer would keep moving and the reading would drift. Non-elastic fabric holds the load still under the hook. It stays soft and flexible, so the baby lies comfortably for the few seconds a reading takes.
The sling is meant for babies up to about 6 months who lie flat and weigh no more than 5 kg. Once a baby can sit up or nears that weight, change to weighing trousers on a scale with a larger range, such as the 25 kg dial spring scale.
Look over both straps and the double-stitched seams at the corners for fraying, loose threads or thin patches. Check that the two straps are the same length, so the panel hangs level. Take a worn sling out of use instead of patching it up during a session.
To request a quotation, send the product name, code and quantity through our contact page or add the item to your enquiry cart.
Last updated: 14 November 2026
For newborns and young infants, this tubular hanging scale reads 0–5 kg in 25 g steps, with a precision of ±25 g. It works without power: hang it from a door frame, beam or tripod, attach a sling or weighing trousers to the lower hook and reset to zero. The pointer settles in less than 3 seconds.
| Parameter | Detail |
|---|---|
| Type | Mechanical infant scale, spring type, tubular |
| Measuring range | 0–5 kg |
| Minimum graduation | 25 g |
| Precision | ±25 g |
| Reading time | Less than 3 seconds |
| Zero setting | Easy zero adjustment / reset-to-zero (tare) function |
| Hooks and handle | 2 non-removable hooks: upper for hanging, lower for a sling or weighing trousers; easy-to-hold handle |
| Materials | Body stainless steel, epoxy-coated steel or ABS-type plastic; dial metal or ABS-type plastic; calibration screw stainless steel or ABS-type plastic |
| Build | Rust-proof mechanics; UV-resistant plastic parts; splash proof, shock resistant, light-weight; smooth finish for cleaning |
| Product code | SLE/AE/02 |
| Minimum order | 10 units |
| Dispatch | Usually within 7 to 10 working days |
| Supplied by | ScienceLab (Jain Scientific Equipments Pvt Ltd), Ambala, India |
Birth-weight record at a home visit. Hang the scale from a door frame or a tripod, hook the sling onto the lower hook and reset to zero with the sling empty. Lay the undressed newborn in the sling, read the weight to the nearest 25 g once the pointer steadies, and write it down with the date.
Follow-up weighing. Use the same scale and the same sling at each visit so that successive readings can be compared. Once the baby nears 5 kg, move to the 25 kg dial spring scale fitted with weighing trousers for the seated child.
No. Weigh the baby undressed, or in a dry nappy only if the room is cold. At 25 g steps, a vest, a blanket or a wet nappy shows on the reading and makes one visit hard to compare with the next.
It can. A feed or a full nappy changes a small baby's weight by an amount the 25 g divisions will show. Weigh at a similar time at each visit, and before a feed where possible, so that changes reflect growth rather than timing.
Hang the empty sling or trousers on the lower hook and use the zero adjustment to bring the pointer back to zero. The scale then shows only the baby's weight. Reset the zero whenever you change to a different carrier.
Keep the scale at the level of your eyes and wait for the pointer to steady, which takes under 3 seconds. Make sure the baby, the sling and your hands touch nothing else. Read to the nearest 25 g mark.
Hang a known mass from the lower hook and compare the reading with its marked value. Do this before a run of home visits and whenever the scale has been dropped. A wrong result can be corrected with the calibration screw.
Any firm point that holds the scale at about eye level will do; give it a firm pull before the baby goes in. The upper hook takes the load. Between houses, carry the scale by its handle with the sling folded away.
To request a quotation, send the product name, code and quantity through our contact page or add the item to your enquiry cart.
Last updated: 14 November 2026
Weighing Trousers hold a baby or young child upright under a hanging spring scale. A pre-shaped seat keeps the child centred, while a 124–130 cm suspension strap runs along both side seams and forms the loop that goes over the scale's lower hook. The double-stitched, non-elastic fabric takes children up to 25 kg.
| Parameter | Detail |
|---|---|
| Type | Weighing trousers with strap for suspension from a spring scale |
| Load capacity | Holds infants/children up to 25 kg |
| Waist | 29 cm (58 cm circumference) |
| Height | 27 cm at centre; 16 cm at the side |
| Crotch width | 11–15 cm |
| Leg openings | 13–14 cm (26–29 cm circumference) |
| Suspension strap | 124–130 cm long, running from the leg opening along the side seams and fixed on both sides of the trousers |
| Fabric and seams | Soft, flexible and non-elastic; easily maintained; double-stitched seams |
| Shape | Pre-shaped for easy placing of the infant |
| Product code | SLE/AE/03 |
| Minimum order | 10 units |
| Dispatch | Usually within 7 to 10 working days |
| Supplied by | ScienceLab (Jain Scientific Equipments Pvt Ltd), Ambala, India |
Two-person weighing at a survey station. One team member hangs the 25 kg dial spring scale at eye level and hooks the strap loop onto its lower hook. The second slips the child's legs through the openings and lowers the child until the trousers carry the weight. The reader calls out the figure and the recorder writes it down.
Rotating pairs in a busy session. Number each pair and set the scale to zero every time a different pair goes on the hook. A soiled pair goes straight into a laundry bag, and the next child goes into a clean one. Wash and dry the used pairs at the end of the day before they are packed again.
Weight and height at one visit. After weighing, the child moves to a portable length-height board for standing height, or lies on it for length if under two years old. Babies who cannot yet sit skip the trousers and are weighed lying flat in the infant weighing sling.
Hang the empty trousers from the scale by the strap loop and set the zero. Hold the child under the arms, slip both legs through the leg openings and lower the child slowly until the trousers take the full weight. The feet should hang clear of the floor before you read.
Yes, check the zero with the empty trousers hanging before each child. Re-set it whenever a different pair goes on the hook, because washed pairs can differ slightly in weight. The check takes a few seconds and keeps each reading true to the child alone.
Lift the child out, hang a clean pair, zero the scale again and repeat the weighing. Put the soiled pair aside for washing and do not use it again that day. Carrying several pairs to each session keeps the queue moving when this happens.
Not as a first choice. The trousers are pre-shaped for a child who sits upright. A newborn who must lie flat is better weighed in the sling for use with a scale, which holds up to 5 kg. A heavier child who cannot sit can be held by an adult on the mother and child scale.
Check that the leg openings sit loosely around the thighs and that nothing pinches at the crotch. Keep the caregiver in sight, talk to the child, and lift the child out as soon as the reading is taken. Lower a sick child more slowly and support the back while placing them.
Explain that the trousers carry the child for only a few seconds and let the caregiver help place the child. If they still object, the caregiver can stand on the mother and child scale holding the child, so the trousers are not needed.
To request a quotation, send the product name, code and quantity through our contact page or add the item to your enquiry cart.
Last updated: 14 November 2026
Fitted at admission or registration, this red identification band stays on a child's wrist until it is cut off. The transparent, non-stretch plastic takes details written with a ballpoint pen, or a paper strip slipped inside, and its clip locks once and cannot be reopened. Centres often use red to mark one group of children and blue for another.
| Parameter | Detail |
|---|---|
| Type | Personal identification bracelet for paediatric use; single use, tamper proof, transparent, non-stretch |
| Colour | Red |
| Band material | Supple non-stretch plastic, LDPE-based, vinyl or equivalent |
| Resistance | Water, common solvents and soaps |
| Feel | Strong and durable, soft to the touch |
| Closure | Strong single-use clip that cannot be removed once clicked into position |
| Writing | Common ballpoint pen directly on the band (non-erasable), or on a paper strip inserted inside the transparent band |
| Dimensions | Approximately 1 cm x 25 cm (w x l) |
| Length adjustment | Adjustable at the closure; the free end can be trimmed next to the clip |
| Product code | SLE/AE/04 |
| Minimum order | 10 units |
| Dispatch | Usually within 7 to 10 working days |
| Supplied by | ScienceLab (Jain Scientific Equipments Pvt Ltd), Ambala, India |
Fitting at intake. Write the child's name, number and date, let the ink dry, then wrap the band round the wrist, leaving a little slack. Press the clip until it locks and cut the spare tail close to the clip. The child then moves on to the MUAC tape and the spring-type infant scale.
Checking at each contact. Before a weight from the Electronic Scale Baby or any other measurement goes into the register, staff read the band aloud and match it with the register entry. A band that has slipped or faded is replaced on the spot.
Removal at discharge. When the child leaves the ward or programme, cut the band with blunt-ended scissors next to the clip and throw it away. The removal date goes into the register with the final measurements.
Snug, but with room for one finger between the band and the wrist. Adjust the length at the closure, press the clip until it locks, then trim the free end next to the clip so it cannot catch on bedding or clothes. The band is about 1 cm wide and 25 cm long before trimming.
No. The clip is single use and cannot be removed once it clicks into position, and the plastic does not stretch over the hand. The only way to take the band off is to cut it, so a cut or missing band shows at once that it has been removed.
Fit it at admission or registration, before weighing or any other step, so every record that follows can be matched to the child. It then stays on for the whole stay or programme period and is checked at each contact.
Not on this band itself; what red stands for is set by your facility. Many hospitals already use red to flag allergies, so check the local colour scheme first. Where red is free, it can mark one enrolment group while blue marks another.
The band is soft to the touch and made of supple plastic, strong enough to last a long stay. During routine care, check the fit and the skin under the band. Replace it with a new band if it has become tight or if the details are fading.
To request a quotation, send the product name, code and quantity through our contact page or add the item to your enquiry cart.
Last updated: 14 November 2026
A blue, transparent wristband that gives each child in a clinic, nutrition programme or survey a personal identity tag. Details are written straight onto the band with a ballpoint pen, or onto a paper strip slid inside it, and a single-use clip locks it shut. Many centres pair blue bands with red ones to mark two groups.
| Parameter | Detail |
|---|---|
| Colour | Blue |
| Use | Paediatric personal identification; single use |
| Band | Transparent, tamper proof, supple non-stretch plastic (LDPE-based, vinyl or equivalent) |
| Chemical resistance | Resistant to water, common solvents and soaps |
| Feel | Soft to the touch; strong and durable |
| Locking | Single-use clip; once clicked into position it cannot be removed |
| Recording details | Ballpoint pen directly on the band (non-erasable), or on a paper strip slid into the transparent band |
| Size | Approximately 1 cm wide x 25 cm long |
| Fitting | Length adjusts at the closure; excess strap can be trimmed where it leaves the clip |
| Product code | SLE/AE/05 |
| Minimum order | 10 units |
| Dispatch | Usually within 7 to 10 working days |
| Supplied by | ScienceLab (Jain Scientific Equipments Pvt Ltd), Ambala, India |
Pre-written survey bands. Before a field round, the team writes the household or survey number on a batch of blue bands and lets the ink dry. On site, the child's name is added, the band is fitted and the same number goes on the record sheet beside the mother and child scale reading.
Two-colour sorting. In a feeding programme, children in one enrolment group wear blue and those in another wear the red ID band, following the centre's own protocol. Staff can then call one group at a time to the infant clinic scale without reading every tag.
Desk preparation with inserts. When many bands are made up before a session, staff fill in the paper strips first and check each name against the register. Each strip then slides into a clear band, ready to fit as the child arrives for MUAC screening.
Use an ordinary ballpoint pen. Details written directly on the band cannot be rubbed off. Press firmly, keep the letters clear and let the ink dry for a moment before fastening, so nothing smears while the band is handled.
Use the insert when bands are prepared in advance at a desk, because the strips can be filled in and checked against the register first. Write on the strip with a ballpoint pen, then slide it into the transparent band so the text lies flat behind the plastic. Writing directly on the band is quicker for a single admission.
When all bands follow one pattern, staff know where to look and what each colour stands for. Agree which group wears blue, which details go on the band and in what order, and which wrist is used. Then keep to that pattern at every session.
Pause the task and confirm the child's identity with the caregiver and the register before going on. Cut off the old band if it is still in place, write a fresh blue band and fit it. Never write over faded details on a band that is already fastened.
Yes. It is made of supple non-stretch plastic that resists water, common solvents and soaps, so it can stay on through bathing and hand washing. Check the writing at each visit and replace a band whose details have become hard to read.
To request a quotation, send the product name, code and quantity through our contact page or add the item to your enquiry cart.
Last updated: 14 November 2026
A plain, numerically graduated tape for measuring an adult's mid-upper arm circumference (MUAC) up to 50 cm. It carries no colour bands: it gives the actual reading in 1 mm divisions, which the user compares with their own protocol. The tape is non-tear, stretch-resistant plasticised synthetic paper with permanent print that stays readable in low light.
| Parameter | Detail |
|---|---|
| Type | MUAC measuring tape for adults, without colour code |
| Range | Up to 50 cm |
| Graduation | 1 mm |
| Accuracy | ±1 mm of the maximum measurement (50 cm) |
| Operating temperature | 0°C to +40°C |
| Material | Non-tear, stretch-resistant plasticised synthetic paper |
| Thickness | Minimum 0.3 mm |
| Permanent, resistant to solvents, easily readable in low light | |
| Product code | SLE/AE/06 |
| Minimum order | 10 units |
| Dispatch | Usually within 7 to 10 working days |
| Supplied by | ScienceLab (Jain Scientific Equipments Pvt Ltd), Ambala, India |
Marking and reading. The person stands with the elbow bent at a right angle. The measurer finds the tip of the shoulder and the tip of the elbow, measures between them and marks the halfway point on the skin. With the arm hanging loose again, the tape goes round at the mark and the reading is taken to the nearest millimetre.
Part of a full adult assessment. Record the arm reading with body weight from the adult physician scale and standing height from the baby, child and adult length/height board. Writing all three on one form at the same visit keeps the assessment complete.
Observer practice in class. In a nursing or dietetics session, pairs measure the same volunteers twice each and compare results. The class looks at how far repeat readings drift and why: a misplaced mark, a loose or tight tape, or a sleeve left on. Trainers who also teach child screening can show the colour-banded child MUAC tape alongside.
Ask the person to bend the elbow to a right angle with the forearm across the body. Find the bony tip of the shoulder and the point of the elbow, measure the distance between them with the tape and mark the halfway point. Then let the arm hang relaxed before measuring round it.
Snug enough to touch the skin all the way round, but not so tight that it presses into the soft tissue. Keep the tape level, parallel to the floor, at the marked midpoint. A gap under the tape gives a high reading and a squeezed arm gives a low one.
Use the arm your protocol names, often the left or non-dominant arm, and use the same arm at every visit. Measure on bare skin, because a sleeve rolled up tightly above the mark or left under the tape changes the result.
Small differences in tape position and tension make each reading vary a little, both for one measurer and between staff. Take two readings, re-wrapping the tape each time, and take a third if they differ by more than your protocol allows. Record the average to the nearest millimetre.
Yes. Tapes differ in design and thickness, and a thicker tape can read slightly differently on the same arm. This tape is stretch resistant with a minimum thickness of 0.3 mm. Use one tape type throughout a survey or a patient's follow-up, and note the type in your records.
Wipe it between people with a cloth moistened with a mild cleaning agent; the print is permanent and solvent resistant. Store it flat and dry. From time to time, lay it along a steel rule to check for stretch, and withdraw any tape that is creased, cut or hard to read.
To request a quotation, send the product name, code and quantity through our contact page or add the item to your enquiry cart.
Last updated: 14 November 2026
A colour-banded tape for measuring a child's mid-upper arm circumference during nutrition screening. The reading falls in a red zone up to 11.5 cm, a yellow zone from 11.5 to 12.5 cm or a green zone above that. The tape is also graduated in 1 mm steps up to 26.5 cm, so an exact figure can be written down as well as the colour.
| Parameter | Detail |
|---|---|
| Type | Child MUAC measuring tape, colour coded |
| Range | Up to 26.5 cm |
| Graduation | 1 mm, with a thicker line at 21.0 cm |
| Accuracy | ±1 mm of the maximum measurement (26.5 cm) |
| Red zone | 0 to 11.5 cm (Pantone 1795 C) |
| Yellow zone | 11.5 to 12.5 cm (Pantone 107 C) |
| Green zone | 12.5 to 26.5 cm (Pantone 369 C) |
| Operating temperature | 0°C to +40°C |
| Material and print | Non-tear, stretch-resistant plasticised synthetic paper, minimum thickness 0.3 mm; permanent, solvent-resistant print, easily readable in low light |
| Product code | SLE/AE/07 |
| Minimum order | 10 units |
| Dispatch | Usually within 7 to 10 working days |
| Supplied by | ScienceLab (Jain Scientific Equipments Pvt Ltd), Ambala, India |
Door-to-door rounds. The health worker measures the child's relaxed arm at the midpoint and notes both the colour at the reading point and the millimetre value. Both go on the record sheet next to the name written on the child's blue ID band or red ID band.
Screening camp stations. After the arm reading, each child moves on to the spring-type infant scale with weighing trousers, then to the length/height board. Keeping the same order at every camp means no step is missed when queues are long.
Caregiver practice. On a training day, each caregiver measures their own child while the trainer watches, then repeats it while the trainer checks tape tension and the reading point. Any reading that differs from the trainer's is taken again together until the two agree.
Checking a new batch. When tapes arrive, compare the red, yellow and green bands against the programme's colour references. The tape lists Pantone 1795 C, 107 C and 369 C, so a printed swatch card is enough for a quick check.
The tape is red from 0 to 11.5 cm, yellow from 11.5 to 12.5 cm and green from 12.5 to 26.5 cm. The tape itself does not decide anything: how each colour is interpreted and acted on, and for which age group, follows your national or programme guidelines.
Read it at the reading point, where the end of the tape meets the scale after it has been passed round the arm. Note the colour under that point and the millimetre value. Look straight down at the tape, not from an angle, so you do not read the line next to it.
The usual ones are pulling the tape so tight that it pinches the skin, leaving it so loose that it gapes, and measuring above or below the midpoint. A tensed or bent arm also changes the result, so let the arm hang loosely at the side before you wrap the tape.
Not to take the reading, but the colour bands apply only to the age group named in your programme protocol, so check that the child falls within it. Do not read the colours for anyone outside that group. Measure them as their own protocol says, for example with a plain numerical tape such as the MUAC, Adult, Without Color Code.
Show the method first on a child while the caregiver watches. Then let the caregiver measure while you check the arm position, the tension and the reading point. Practise until both of you get the same colour and value. The colour method is quick to learn, so short refresher sessions are usually enough.
To request a quotation, send the product name, code and quantity through our contact page or add the item to your enquiry cart.
Last updated: 14 November 2026
Hung from a hook or beam, this dial-faced spring scale weighs babies and young children from 0 to 25 kg. The dial, 15 to 20 cm across, reads in 100 g divisions and in kilograms only. A damping mechanism steadies the pointer when a toddler moves, and a reading takes less than 15 seconds.
| Parameter | Detail |
|---|---|
| Type | Spring-type mechanical scale for infants, dial face |
| Measuring range | 0–25 kg |
| Minimum graduation | 100 g |
| Readout and dial | Metric (kg) only; dial 15 to 20 cm in diameter, readable in low light |
| Reading time | Less than 15 seconds |
| Zero setting | Easy zero adjustment / reset-to-zero (tare) function |
| Stabilising | Damping mechanism for faster reading |
| Hooks | 2 non-removable hooks: upper for hanging, lower for weighing trousers or a sling; stainless steel or high-grade galvanised steel |
| Materials and build | Dial metal or ABS-type plastic; body stainless steel, epoxy-coated steel or ABS-type plastic; splash proof, shock resistant, light-weight |
| Product code | SLE/AE/08 |
| Minimum order | 10 units |
| Dispatch | Usually within 7 to 10 working days |
| Supplied by | ScienceLab (Jain Scientific Equipments Pvt Ltd), Ambala, India |
Monthly growth-monitoring session. Hang the scale from a beam at the reader's eye level, fit weighing trousers to the lower hook and set the pointer to zero. Lower the child in, wait for the needle to settle and write the weight to the nearest 100 g on the growth card. Arm circumference follows with a child MUAC tape.
Field check with a known mass. At the start of a session, hang a slotted mass hanger from the lower hook and confirm the dial reading. A wrong result calls for the calibration screw, and the check goes into the team's log.
Training on reading the dial. Students take turns reading the same load from straight in front and then from an angle, and record both figures. The gap between them shows why the scale must hang at the reader's eye level and why the dial is always read straight on.
Hang the upper hook from a firm beam, tripod or door frame so the scale swings freely and does not touch a wall. The dial should sit at the reader's eye level. Reading it from below or from the side gives a parallax error.
Let the mother stay close and talk to the child, and lower the child into the trousers quickly and gently. The damping mechanism calms the swing, so the pointer settles once the child is still. If the struggling goes on, lift the child out, calm them and try again.
No. It is a mechanical spring scale, so it works on outreach visits with no electricity at all. All it needs is a firm point to hang from and a carrier on the lower hook.
Wipe off dust and moisture and store the scale dry with nothing hanging from it, so the spring is not left under load. Before the next session, check that the pointer returns to zero with both hooks empty.
Children who can sit are weighed in weighing trousers rated to 25 kg. Newborns who need to lie flat go in a sling. Neither carrier comes with the scale. Wash the trousers between sessions and keep a spare pair in the kit.
To the nearest 100 g, the smallest division on the dial, which suits babies and young children up to 25 kg. Where small changes in a newborn matter, a finer scale such as the 25 g tubular spring scale is the better choice.
To request a quotation, send the product name, code and quantity through our contact page or add the item to your enquiry cart.
Last updated: 14 November 2026
A mechanical beam scale for weighing babies lying in a removable curved tray. It covers 0–16 kg in 10 g divisions and needs no batteries or mains power. Adjustable feet and a built-in round level bubble set it level, and a stabilising mechanism brings a reading in about 30 seconds.
| Parameter | Detail |
|---|---|
| Type | Beam-type mechanical scale for infants |
| Measuring range and graduation | 0–16 kg in 10 g divisions |
| Readout and display | Metric (kg); signal-white numbers on a black surface, readable in low light |
| Reading time | About 30 seconds, with stabilising mechanism |
| Zero setting | Easy zero adjustment |
| Tray | Removable curved tray, powder-coated, light grey |
| Levelling | Adjustable feet; built-in round level bubble with centre indication |
| Body and calibration screw | Metal only (stainless steel or epoxy-coated steel); stainless steel calibration screw |
| Protection and build | Rust-proof mechanics; UV-resistant plastic parts; splash proof, shock resistant, light-weight; smooth finish for cleaning and disinfection |
| Product code | SLE/AE/09 |
| Minimum order | 10 units |
| Dispatch | Usually within 7 to 10 working days |
| Supplied by | ScienceLab (Jain Scientific Equipments Pvt Ltd), Ambala, India |
Daily set-up. Place the scale on a firm table and turn the feet until the bubble sits in the centre. With the empty tray in place, plus any cloth that will be used, set the beam to zero. Weigh the undressed baby, then move to the child length-height board for recumbent length.
Function check with known masses. Put a brass mass set in the tray, balance the beam and compare the reading with the marked value. Repeat with a larger load. If the zero or the readings have drifted, adjust with the calibration screw and note it in the equipment log.
Skills-lab comparison. Nursing students weigh the same weighted doll on this beam scale and on an electronic baby scale, then discuss why the readings differ and how long each method takes. The exercise teaches levelling, zeroing and reading a beam straight on.
A beam scale balances correctly only when it stands level. On a sloping or soft surface the zero shifts and every reading carries the error. Use a firm, flat table, turn the adjustable feet until the bubble is centred, and only then set the zero.
Lay the cloth in the tray first and set the zero with it in place. The beam then reads the baby's weight alone. If cloths of different thickness are used, set the zero again each time the cloth changes.
Yes, as long as the room is warm. Clothes and a wet nappy add weight that shows on the reading and makes visit-to-visit comparison unreliable. If a nappy has to stay on, use a dry one and note it in the record.
Check that nothing touches the tray or the beam, such as a cloth hanging over the edge or the scale standing against a wall. Make sure the tray is seated properly and the scale is level. If the beam still sticks, have the mechanism checked before further use.
About 30 seconds. The stabilising mechanism damps the beam's movement so that it settles sooner. A beam scale is slower than an electronic one, but it keeps working where there is no power supply.
Lift out the curved tray, wipe it with a cloth and the disinfectant your clinic uses, and dry it before refitting. The powder-coated finish and smooth body make this quick. Clean the whole scale at the end of each day.
To request a quotation, send the product name, code and quantity through our contact page or add the item to your enquiry cart.
Last updated: 14 November 2026
Standing adults are weighed on this floor-standing beam scale from 6 kg up to 180 kg, in 100 g steps. Black numbers on a silver surface can be read from both sides, so the clinician and the person on the platform both see the result. It has an attached hand pole and adjustable feet, but no height rod.
| Parameter | Detail |
|---|---|
| Type | Beam-type mechanical scale for adults |
| Capacity | 6–180 kg |
| Minimum graduation | 100 g |
| Readout and display | Metric (kg); black numbers on a silver surface, readable from both sides and in low light |
| Reading time | Less than 15 seconds, with stabilising mechanism |
| Zero setting | Easy zero adjustment |
| Hand pole and height rod | Hand pole attached; height rod not included |
| Levelling | Adjustable feet for horizontal levelling |
| Body and calibration screw | Metal only (stainless steel or epoxy-coated steel); stainless steel calibration screw |
| Product code | SLE/AE/010 |
| Minimum order | 10 units |
| Dispatch | Usually within 7 to 10 working days |
| Supplied by | ScienceLab (Jain Scientific Equipments Pvt Ltd), Ambala, India |
Adult assessment station. Weigh the person on the beam scale, then measure standing height on a portable length-height board, since this model has no rod. Mid-upper arm circumference taken with an adult MUAC tape completes the record.
Accuracy check. With the platform empty, confirm the zero. Then stack enough cast alloy masses of known value in the centre of the platform to pass the 6 kg lower limit, and compare the beam reading with their total. Adjust with the calibration screw if the zero has drifted, and log the date of the check.
Antenatal or occupational-health follow-up. Weigh each person on the same scale, at a similar time of day, without shoes or heavy items, so that monthly readings can be compared. Write the figure down straight away rather than from memory.
Turn the adjustable feet until the platform sits firm and does not tilt when pressed at each corner. Use a hard, level floor; a soft mat or uneven tiles let the base move during weighing and upset the beam.
With nobody on the platform and the beam set to zero, use the zero adjustment until the beam floats level at its balance mark. Check the zero at the start of each session and after the scale has been moved.
Only for balance while stepping on and off. Once on the platform, the person stands still in the centre with arms by the sides. Leaning on or gripping the pole moves part of the body weight off the platform, and the reading falls.
Use a separate measuring board, such as the Portable Baby/Chd/adult L-H, which reads standing height up to 204 cm. Measure barefoot with heels, buttocks and head against the board, and record the height straight after the weight.
Use the same scale at a similar time of day, with shoes and heavy items removed and similar light clothing. Check the zero before each session. Changes between visits then reflect the person rather than the method.
Yes, if the person stands facing away from the beam. The figures can be read from both sides, so the health worker reads the result from where they stand without showing it. A person who wants to know can face the beam and watch instead. Weigh in a screened space where possible.
To request a quotation, send the product name, code and quantity through our contact page or add the item to your enquiry cart.
Last updated: 14 November 2026
The Portable Baby/Chd/adult L-H is one folding board for the whole household. Babies up to 24 months lie on it for recumbent length, from a minimum of 0 cm, while older children and adults stand against it for height. Fitted with two extensions it reads 0–204 cm; with one, 0–142 cm. The scale is divided in 0.1 cm steps.
| Parameter | Detail |
|---|---|
| Measures | Recumbent length of babies up to 24 months (minimum length 0 cm); standing height of children from 24 months and adults |
| Range with two extensions | 0–204 cm |
| Range with one extension | 0–142 cm |
| Graduation and accuracy | Centimetres, smallest graduation 0.1 cm; accuracy ±0.2 cm, precision ±0.2 cm |
| Scale and width | Integrated, hard-wearing scale with numerals along the board, readable in low light; board about 25 cm wide |
| Measuring slide | Glides smoothly; lockable or friction-held; wobble of about 0.2 cm at most over the full length; reading point marked by arrow or pictogram |
| Folding and carrying | Folds up; panels held by self-contained spring-loaded bolts; handle at the point of balance and/or removable shoulder or back strap |
| Set-up | No tools needed; no calibration needed, as all parts have fixed positions |
| Construction | Light, strong material with a smooth finish for cleaning; resists high humidity and heat; water splash proof and shock resistant |
| Product code | SLE/AE/011 |
| Minimum order | 10 units |
| Dispatch | Usually within 7 to 10 working days |
| Supplied by | ScienceLab (Jain Scientific Equipments Pvt Ltd), Ambala, India |
Household survey round. Measure each family member in turn: babies lying with the board flat, everyone else standing barefoot with it upright. Weigh the same people on a mother and child scale and take arm circumference with an adult MUAC tape, so one visit gives a complete record for the family.
School health check-up. Pupils stand against the upright board with heels, buttocks and head touching it, and the slide comes down onto the crown. Weight comes from bathroom scales at the next station, and the class works out each pupil's BMI from the two figures.
Checking the board before a survey. Lay a metre scale along the board and compare its marks with the board's divisions at several points. Confirm that the slide locks, that the bolts hold each panel firm and that the head piece stands square on the floor; a spirit level on the upright board shows any lean.
Lying down. Babies up to 24 months are measured for recumbent length with the board flat on a table or the floor. From 24 months, children stand against the upright board for height. Lying length usually reads slightly more than standing height, so always note which position was used.
Barefoot, feet together, with heels, buttocks, shoulders and the back of the head touching the board. The person looks straight ahead and breathes normally. Bring the slide down firmly onto the crown, pressing the hair flat, lock it and read at the arrow.
Small changes in posture, hair caught under the slide, shoes left on or a slide that was not locked all shift the result. Height also drops slightly through the day. Measure barefoot at a similar time, and take the reading again if two results disagree.
With one extension the board reads 0–142 cm, which covers babies and younger children. Fit the second extension to reach 0–204 cm when taller children and adults are measured. On mixed household visits, keep both extensions fitted.
BMI divides weight by the square of height, so a height error counts twice over. A reading that is slightly short pushes the BMI up. Reading to the nearest 0.1 cm at the arrow keeps this error small.
Wipe the surface and the slide with a damp cloth and let them dry. Fold the panels until the spring-loaded bolts hold them, then carry the board by its handle or strap. Fold it before loading it into a vehicle, as the bolts keep the parts from shaking loose.
To request a quotation, send the product name, code and quantity through our contact page or add the item to your enquiry cart.
Last updated: 15 November 2026
Sized for children only, this fold-up board reads 0–120 cm in 0.1 cm steps on a metal scale. Laid flat, it takes the recumbent length of babies up to 24 months. Stood upright on its adjustable feet, it takes the standing height of children from 24 months. Accuracy and precision are both given as ±0.2 cm.
| Parameter | Detail |
|---|---|
| Measures | Recumbent length of babies up to 24 months; standing height of children aged 24 months and above |
| Measurement range | 0–120 cm |
| Graduation | Centimetres; smallest graduation 0.1 cm |
| Accuracy and precision | ±0.2 cm each |
| Measurement scale | Metal, fully integrated; numerals along the board; readable in low light; board about 25 cm wide |
| Foot/head piece | Large piece with adjustable feet for uneven floors; base when upright, headboard when flat |
| Measuring slide | Smooth gliding; lockable or friction-held; reading points marked with arrow or pictogram |
| Folding and carrying | Fold-up, low weight; spring-loaded bolts or spring clasps; integrated handle plus removable shoulder or back strap |
| Set-up | No tools and no calibration needed; all parts have fixed positions |
| Product code | SLE/AE/012 |
| Minimum order | 10 units |
| Dispatch | Usually within 7 to 10 working days |
| Supplied by | ScienceLab (Jain Scientific Equipments Pvt Ltd), Ambala, India |
Under-two length check. Lay the board flat with the headpiece at one end. One measurer cups the baby's head against it while the second keeps the body straight, presses gently on the knees and brings the wedge against both heels. Weigh the same baby on the newborn spring scale or the 25 kg dial spring scale and record both figures together.
Anganwadi health round. Stand the board upright, turn the adjustable feet until it stops rocking, and measure each child barefoot. Take arm circumference with a child MUAC tape, then weigh the child in weighing trousers on a hanging scale, so each child passes three stations in order.
Training practice. Nursing or public-health students take turns measuring the same child-sized doll, then compare their readings. The spread between results shows where technique slips: a bent knee, a tilted head or a wedge that was not locked before reading.
One person holds the head still against the headpiece while the other straightens the body and legs and moves the wedge. A single measurer cannot do both, and a baby who turns or bends gives a short reading. A parent standing close by can help keep the baby calm.
Rest one hand gently over both knees to press the legs flat, with the toes pointing straight up. With the other hand, slide the wedge until it sits firmly against both heels. Lock it before letting go of the baby, then read at the arrow.
Not well. A flexible tape laid beside a lying baby bends and slips, and there is nothing square at the head or the feet. The board has a fixed headpiece and a sliding wedge that meet the body at right angles, so the length is read between two firm stops.
It needs no calibration, because all its parts have fixed positions. Still, look it over before each session: the slide should glide and lock, the bolts should hold the panels firm and the markings should be clean. Compare the scale with a known length from time to time.
Yes. The large foot piece has adjustable feet. Turn them until the upright board no longer rocks before the child steps on. When the board is laid flat for a baby, the same piece serves as the fixed headboard.
The range ends at 120 cm, so taller children need the full-range baby, child and adult board, which reads to 204 cm with two extensions. Teams that see all age groups often carry one of each.
To request a quotation, send the product name, code and quantity through our contact page or add the item to your enquiry cart.
Last updated: 14 November 2026
A portable electronic floor scale that weighs adults and children from 0.1 to 150 kg in 100 g steps. In its default mother-child mode, the adult is weighed first and then handed the child; the scale tares itself and shows the child's weight alone. It runs on mains, direct solar power or six AA batteries, and weighs no more than 4.0 kg.
| Parameter | Detail |
|---|---|
| Measuring range | 0.1 to 150 kg |
| Graduation and accuracy | 100 g minimum graduation; ±100 g over the entire measuring range |
| Modes and taring | Mother-child mode by default, taring automatically without any button once the parent, weighed first, holds the child; mother-only mode by an operational button |
| Display | Weight fixed within 5 seconds and held for at least 20 seconds after the load is removed or until the next weighing; back-lit LCD for low light; anti-glare, high-contrast screen for bright light |
| Power | Primary: mains via switched-mode AC adapter with multi-country plugs. Secondary: direct solar, panel fully recharged within 2 hours of full sunlight or 4 hours of dappled sunlight, and able to power the scale regardless of charge status. Tertiary: 6 customer-replaceable AA batteries, minimum 5,000 measurements per set |
| Power saving | Automatic switch-off after 4–6 minutes of non-use |
| Portability | Maximum weight 4.0 kg; maximum dimensions 360 mm (L) x 400 mm (W) x 70 mm (H) |
| Feet and foot mat | Adjustable feet for levelling, withstanding a load of 300 kg; light-coloured foot mat to avoid heating in direct sunlight, footprint markings optional |
| Operating conditions and protection | Within ±100 g at up to 80% RH and 0–45°C; IP53; corrosion-resistant load cells and housing; built-in overload protection; transport mode or mechanical feature against damage in transit |
| Product code | SLE/AE/13 |
| Minimum order | 10 units |
| Dispatch | Usually within 7 to 10 working days |
| Supplied by | ScienceLab (Jain Scientific Equipments Pvt Ltd), Ambala, India |
Setting up at a household. Choose a flat, hard floor, level the scale with its adjustable feet and switch it on. Outdoors, leave the solar panel facing the sun; at a clinic, plug in the mains adapter. A spare set of AA batteries stays in the kit as the last back-up.
Weighing a young child with the mother. The mother steps on alone in light clothing and her weight shows. She is then handed the undressed child, the scale tares itself and the child's weight appears. The figure stays on the display for at least 20 seconds after she steps off, so there is time to write it down.
Completing the household round. After weighing, measure each child on the Portable Baby/Chd/adult L-H board and take an arm reading with the colour-coded child MUAC tape. Mothers and other adults have their arm measured with the plain adult MUAC tape.
Training the field team. Before fieldwork starts, measurers practise tared weighing with a colleague holding a doll or a bag of known weight. Each trainee's readings are compared with the trainer's, and anyone outside the agreed limits practises again. Engage the transport mode every time the scale goes back into the vehicle.
Leave the scale in its default mother-child mode. The adult steps on alone and is weighed first. When the adult is then handed the child, taring starts automatically without any button being pressed, and the display shows the child's weight on its own.
Use it for anyone who can stand still on the mat without help, such as older children and adults. Switch to it with the operational button, ask the person to stand in the centre of the foot mat and read the weight directly.
The measurer runs the scale, watches the display and calls out the figure, while an assistant writes it down. The mother stands still in the centre of the mat and holds the child close. Her calm voice and a firm hold keep the child from twisting, which steadies the reading.
Weigh an object of known weight at the start of each day and again after a rough journey. A reading outside the scale's ±100 g accuracy means it should be set aside and a back-up scale used. Weigh the child again whenever a figure looks out of line with earlier visits.
Use mains wherever there is a socket. Away from power, direct solar runs the scale whatever the charge status, and the panel fully recharges within 2 hours of full sunlight or 4 hours of dappled sunlight. Six AA batteries give at least 5,000 measurements, and the scale switches off after 4 to 6 minutes of non-use to save power.
To request a quotation, send the product name, code and quantity through our contact page or add the item to your enquiry cart.
Last updated: 14 November 2026
An electronic scale for weighing babies from 0 to 10 kg, reading in 5 g steps on a large LCD within 5 seconds. TARE removes the weight of a blanket or liner, HOLD keeps the figure on screen after the baby is lifted off, and the scale calibrates itself at every switch-on. It runs on 220 V/50 Hz mains or on replaceable batteries.
| Parameter | Detail |
|---|---|
| Weighing range | 0 to 10 kg |
| Minimum graduation | 5 g |
| Accuracy | ±5 g |
| Display | Large LCD, reading in kilograms |
| Reading time | Maximum 5 seconds |
| Functions | Automatic switch-off, TARE, HOLD, auto-calibration with each switch-on |
| Power | 220 V/50 Hz; customer-replaceable batteries as an additional supply |
| Materials and body | Vital parts rust proof and child-friendly; transparent plastic display cover; light-weight, splash proof and shock resistant body with a smooth surface for cleaning and disinfection |
| Colour | White or similar (off-white, cream, light grey) |
| Product code | SLE/AE/14 |
| Minimum order | 10 units |
| Dispatch | Usually within 7 to 10 working days |
| Supplied by | ScienceLab (Jain Scientific Equipments Pvt Ltd), Ambala, India |
Clinic weighing with a liner. Set the scale on a firm, level table and switch it on so it calibrates. Lay a clean paper liner on the tray and press TARE until the display reads zero. Lay the undressed baby in the centre, wait for the figure to settle and write it down in kilograms.
Weight and length together. Straight after weighing, measure the baby lying down on the Portable Baby/Child L-hgt board. Both figures then go onto the growth record at the same visit, so weight can be read against length.
Back-up and outreach weighing. Keep a beam-type infant clinic scale in the room for days when there is no power and the batteries are flat. For home visits, a spring-type infant scale with a weighing sling does the same job away from the clinic.
Skills practice for trainees. In a nursing skills session, students weigh a training doll on a liner twice, once after pressing TARE and once without it. Comparing the two figures shows how a forgotten tare changes the recorded weight.
Switch the scale on and let it calibrate. Place the blanket or liner on the tray and press TARE so the display returns to zero. Now lay the baby on it. The figure shown is the baby alone, without the weight of the cover.
Yes, for figures that can be compared between visits. Remove clothes and weigh the baby in a clean, dry nappy or none, following your clinic's routine. Clothing and a wet nappy add weight that changes from one visit to the next and can hide the small gains a 5 g scale is meant to show.
Settle the baby first, then lay them flat in the middle of the tray. Wait for the display to stop changing, which takes no more than 5 seconds. If the baby starts to wriggle, press HOLD so the figure stays on screen while you lift the child off and write it down.
In the centre, with the whole body on the tray and nothing resting on the table or the edge. An off-centre position or a hand touching the tray changes the reading. Never step away while the baby is on the scale; keep one hand just above the child without touching.
It reads in kilograms on its LCD, with a minimum graduation of 5 g. Most clinic records and growth charts use metric units, so the figure can be written straight onto the chart without converting from pounds and ounces.
Change the paper liner for every baby. Wipe the tray with a cloth lightly dampened with the clinic's usual surface disinfectant, then dry it. The body is splash proof, so a damp wipe is fine, but do not pour liquid over the scale or put it in water.
To request a quotation, send the product name, code and quantity through our contact page or add the item to your enquiry cart.
Last updated: 14 November 2026
This column scale weighs adults up to 200 kg in 100 g graduations and works out body mass index on its console. A height rod is available with it, so one station gives weight, height and BMI. The low, anti-slip platform is one-piece cast aluminium, and calibration is by push button with a known weight.
| Parameter | Detail |
|---|---|
| Capacity | 200 kg |
| Graduation | 100 g |
| BMI | Calculated automatically |
| Weight stabilisation | MotionLock Technology® helps eliminate unsteady weights |
| Calibration | Push-button, with any known weight over 100 lb (about 45 kg) |
| Platform | One-piece powder-coated cast aluminium; large, anti-slip, set low for easy access |
| Column and console | Anodised aluminium; lightweight, quick assembly; washable surface |
| Height rod | Available with the scale |
| Product code | SCL241 /039 |
| Minimum order | 10 units |
| Dispatch | Usually within 7 to 10 working days |
| Supplied by | ScienceLab (Jain Scientific Equipments Pvt Ltd), Ambala, India |
BMI practical. Students read a partner's height from the rod and weight from the platform, then calculate BMI by hand: weight in kilograms divided by the square of height in metres. They compare the hand figure with the console result and repeat the exercise for each member of the group.
Adult nutrition station. After weight and height, the health worker takes mid-upper arm circumference with an adult MUAC tape and waist circumference with a fibreglass tailor's tape. All four figures go on one card, so each visit's results stay together.
Cross-check between scales. Clinics that also keep a mechanical physician beam scale can weigh the same person on both at the start of a session. A clear difference is a prompt to repeat the push-button calibration with a known weight over 100 lb.
BMI is weight in kilograms divided by the square of height in metres. The console does this sum automatically, so the health worker does not work it out by hand for each person. Height still has to be measured carefully on the rod, because any error there carries into the BMI.
No. Adult BMI uses the same formula for both sexes. The scale gives the number; how it is grouped into categories depends on the charts the health programme follows. For children and teenagers, BMI is read against age- and sex-specific charts instead.
It weighs up to 200 kg and reads in 100 g graduations. The large anti-slip platform sits low, so it is easy to step onto, and the console works out BMI automatically.
Ask the person to stand barefoot and upright on the platform, looking straight ahead. Lower the rod's headpiece until it rests flat on the crown of the head, then read the height. Take the weight with the person standing still in the same place.
Calibration is by push button, using any known weight over 100 lb (about 45 kg). Set the scale on a firm, level floor first. Afterwards, weigh a familiar load or a person of known weight as a check before the session starts.
Shifting weight makes the reading wander. The MotionLock feature helps settle unsteady weights, but the cleanest result still comes when the person stands in the centre of the platform, arms at the sides, until the display holds steady.
To request a quotation, send the product name, code and quantity through our contact page or add the item to your enquiry cart.
Last updated: 14 November 2026
Intended for babies and young children, this electronic scale weighs up to 20 kg with 5 g sensitivity and shows the result on a 60 x 40 mm LCD. A height tape meter and a washable sheet come with it, so weight and length or height can be taken at one visit. An auto-off function saves battery.
| Parameter | Detail |
|---|---|
| Type | Electronic baby scale, handy design |
| Capacity | 20 kg |
| Sensitivity | 5 g |
| Display | LCD, 60 x 40 mm |
| Supplied with | Height tape meter and washable sheet |
| Power saving | Auto-off function to save battery |
| Product code | SCL248 /040 |
| Minimum order | 10 units |
| Dispatch | Usually within 7 to 10 working days |
| Supplied by | ScienceLab (Jain Scientific Equipments Pvt Ltd), Ambala, India |
Growth-monitoring visit. Spread the washable sheet, place the undressed baby in the centre and read the weight once the figure settles. Measure length with the height tape or, where a rigid board is preferred, on the child length-height board. Plot both results on the growth chart against the child's exact age.
Pre-session check with known masses. Before the first child, place a brass mass set on the scale and confirm that the display shows the marked value, then repeat with a heavier combined load. Write the result in the equipment log so that any drift is noticed early.
Nutrition screening corner. Alongside weight and length, health workers take arm circumference with a child MUAC tape and write all three figures on the child's card before the family leaves.
Weigh the sheet alone once at the start of the session and subtract that figure from each baby's reading. If the display shows zero when the scale is switched on with the sheet already in place, no subtraction is needed. Use the same sheet for the whole session.
Calm the baby first, with the parent close by, and keep your own hands off the scale. Wait until the figure stops changing before writing it down. If the baby will not settle, try again a few minutes later rather than recording a guess.
Babies under two are measured lying flat, with one person holding the head and another straightening the legs while the tape runs from crown to heel. Older children stand barefoot against a wall with the tape fixed upright. Record the result in centimetres beside the weight.
The auto-off function shuts the scale down when it is left idle, which saves battery between children. Switch it on again, wait for zero and carry on. Keeping spare batteries in the clinic kit avoids a pause in the middle of a session.
Write the weight and the date in the record in ink first. Then plot the point on the chart in pencil against the child's exact age, using the chart for the child's sex. Pencil lets a misplaced point be corrected cleanly.
Only up to 20 kg, which covers babies and young children. Heavier children and adults need the adult scale with height rod, which weighs up to 200 kg.
To request a quotation, send the product name, code and quantity through our contact page or add the item to your enquiry cart.
Last updated: 14 November 2026