Water Bath (Copper)

Product Code : “SCL352/075”

Water Bath (Copper) (Product Code: SCL352/075) is a 6 inch hemispherical water bath made of copper sheet, used in biology practicals to heat test tubes and small vessels gently in hot water rather than over a direct flame. It has two handles and a set of concentric rings that adjust the opening to the vessel. It is made by Jain Scientific Equipments Pvt Ltd (ScienceLab), an OEM manufacturer, at its own factory in Ambala, India.

Specifications

ParameterDetail
Diameter6 inch (approx. 152 mm)
ShapeHemispherical
MaterialCopper sheet
HandlesTwo
RingsSet of concentric rings
Product codeSCL352/075
ManufacturerJain Scientific Equipments Pvt Ltd (ScienceLab) — OEM
Country of originIndia (made in Ambala, Haryana)

What Is the Copper Water Bath Used For in Biology?

In the Benedict's test for reducing sugars, tubes of food extract and reagent are stood in the boiling water bath for a few minutes until a coloured precipitate forms. In the starch test on leaves, a leaf softened in hot water is placed in a tube of alcohol, and that tube is warmed in the bath so the chlorophyll is removed without bringing the alcohol near a naked flame.

Teachers also use the bath for simple enzyme and temperature experiments, adjusting the flame and checking the water with a thermometer. Keep the water well above the base of the tubes, stand tubes in a small beaker if they tend to tip, and dry the bath after class to keep the copper in good condition. It is a basic item of biology lab equipment in India for secondary schools.

OEM Manufacturer

The Water Bath (Copper) is made by ScienceLab — the trading name of Jain Scientific Equipments Private Limited — at the company's own licensed factory at Saha, Ambala, Haryana, India. As the OEM, the company supplies biology departments, colleges, dealers and importers directly, and handles replacement rings and repeat orders itself — ask us.

More about the manufacturer is on the ScienceLab profile.

Related Laboratory Equipment

Reagents and heating items used with this bath in biology practicals:

See more in the Biology Lab category.

Frequently Asked Questions

What size is the Water Bath (Copper) SCL352/075?
The Water Bath (Copper) SCL352/075 is 6 inches (about 152 mm) in diameter and hemispherical in shape. It is made of copper sheet and has two handles and a set of concentric rings to suit different test tubes, beakers and dishes.

Why use a water bath for the Benedict's test?
A boiling water bath such as the Water Bath (Copper) heats all the Benedict's test tubes evenly at the same temperature, so colour changes can be compared fairly, and it avoids the bumping and spitting that happen when tubes are heated directly in a flame.

Can alcohol be warmed in the Water Bath (Copper)?
Yes, this is a common use: a test tube of alcohol containing a leaf is stood in hot water in the Water Bath (Copper) to remove chlorophyll. Turn the burner off first, because alcohol vapour must never reach a naked flame.

Who manufactures the Water Bath (Copper) SCL352/075?
Jain Scientific Equipments Pvt Ltd (ScienceLab) manufactures the Water Bath (Copper) SCL352/075 as the OEM at its own licensed factory in Saha, Ambala, Haryana, India, and supplies it direct to schools, colleges, dealers and importers.

What is the difference between the two copper water bath listings?
The Water Bath (Copper) SCL352/075 is listed at 6 inches in diameter in copper sheet, while Water Bath Copper SCL-602/049 is listed at 150 mm in thick copper sheet weighing 3 to 4 kg. Both are hemispherical with concentric rings and two handles.

What should a quotation request for the Water Bath (Copper) include?
Include the product code SCL352/075, the number of Water Bath (Copper) units, your delivery address, and any burners, tripods or gauzes you need. Quotations come directly from ScienceLab as the manufacturer, for delivery in India or international markets.

Request a Quote

Ask for a quotation on the Water Bath (Copper) (SCL352/075) via the contact page or add it to the enquiry cart; you will hear back directly from the manufacturer.

Last updated: 24 September 2026

Quadrat

Product Code : SCL353/076

Quadrat (Product Code: SCL353/076) is a square sampling frame of plastic-coated steel, divided into 25 sub grids, used to measure plant cover, density and frequency in ecology field studies. Students in schools, colleges and field courses lay it on grassland, lawns, forest floors or shorelines to compare species within a fixed area. It is made by Jain Scientific Equipments Pvt Ltd (ScienceLab), an OEM manufacturer, at its own factory in Ambala, India, as a core item of botany lab equipment.

Specifications

ParameterDetail
MaterialSteel, plastic coated
ShapeSquare, subdivided into a square grid
Sub grids25
Other optionsAvailable in different sub grids
Product codeSCL353/076
ManufacturerJain Scientific Equipments Pvt Ltd (ScienceLab) — OEM
Country of originIndia (made in Ambala, Haryana)

What Is the Quadrat Used For?

Students place the quadrat at random points, for example using coordinates drawn from random numbers, or at fixed intervals along a transect running from one habitat into another. Inside the frame they count individual plants to work out density, estimate percentage cover from the small squares a species fills, or record whether a species is present in each of the 25 sub grids to calculate its frequency. Repeating this across many placements lets a class compare trampled and untrampled grass, sun and shade, or the zones of a pond margin.

Decide the placement method before starting and use it every time, so the results are free of bias. The plastic coating shields the steel from damp soil and wipes clean, so rinse off mud and let the frame dry before storing it flat. A set of quadrats turns an outing into a proper data exercise and is the backbone of any ecology science kit for schools and colleges.

What to Specify When Ordering

  • The sub-grid division: 25 sub grids as listed, or one of the other sub-grid patterns available.
  • The frame size your syllabus or field manual specifies, since it is not stated in this listing.
  • The number of quadrats needed, for example one per student group.
  • Product code SCL353/076 and the delivery address for the quotation.

OEM Manufacturer

Jain Scientific Equipments Private Limited, trading as ScienceLab, is the OEM (original equipment manufacturer) of this quadrat. The plastic-coated steel frame is made at the company's own licensed factory at Saha, Ambala, Haryana, India, and supplied factory-direct to schools, colleges, field-study centres, dealers and importers. Because the maker handles every order itself, requests for a different sub-grid pattern or a repeat class set can simply be raised with us. More on our company profile.

Related Biology Lab

Equipment that goes out on the same ecology field survey:

Browse the full Biology Lab category for more field and lab apparatus.

Frequently Asked Questions

How many sub grids does the Quadrat have?
The Quadrat (SCL353/076) is divided into 25 sub grids. Other sub-grid divisions are also available, so if your ecology practical calls for a different pattern, mention it in your enquiry and we will confirm the option.

What size is the Quadrat frame?
The frame size of the Quadrat is not stated in the product listing. Contact us with the dimensions your syllabus or field manual specifies, and the manufacturer will confirm what can be supplied before you order.

What is the Quadrat made of?
The Quadrat is made of steel with a plastic coating. The steel keeps the square frame rigid when it is dropped onto grass or soil, while the coating protects it from damp ground and wipes clean after fieldwork.

How do I calculate frequency with the Quadrat's 25 sub grids?
Each sub grid of the Quadrat is one twenty-fifth of the frame, or 4 per cent. Count the small squares in which a species occurs and multiply by 4 to get its percentage frequency for that placement.

Who manufactures the Quadrat?
The Quadrat is manufactured by Jain Scientific Equipments Pvt Ltd (ScienceLab) as the OEM. It is made at the company's own licensed factory at Saha, Ambala, Haryana, India, and quotations for single frames or class sets come directly from the manufacturer.

Can ScienceLab supply a class set of Quadrats or an export order?
Yes. Send code SCL353/076, the number of Quadrats and your delivery details; ScienceLab supplies schools, colleges, dealers and importers in India and international markets direct from its Ambala factory.

Request a Quote

For pricing on the Quadrat, send your enquiry through our contact page or add it to the enquiry cart with the rest of your field-survey kit; the quotation comes straight from the manufacturer.

Last updated: 24 September 2026

Wire Gauze 6 Inch with Ceramic Centre

Product Code : SCL357/078

Wire Gauze (Product Code: SCL357/078) is a 6" square iron-wire gauze with a ceramic circle in the centre, used on a tripod to spread a burner's heat evenly under beakers, flasks and dishes. It has rolled smooth edges and belongs on every bench where glassware is heated in school chemistry and biology practicals. It is made by Jain Scientific Equipments Pvt Ltd (ScienceLab), an OEM manufacturer of biology lab equipment in India, at its own factory in Ambala.

Specifications

ParameterDetail
Size6" (listed as 6" dia)
MaterialIron wire, extra-strong quality
ShapeSquare
CentreCeramic circle provided
Wire edgesRolled smooth
Product codeSCL357/078
ManufacturerJain Scientific Equipments Pvt Ltd (ScienceLab) — OEM
Country of originIndia (made in Ambala, Haryana)

What Is the Wire Gauze Used For?

The gauze is laid on a tripod with a Bunsen burner or spirit lamp underneath, and the beaker, flask or dish sits on top. The ceramic centre lies directly over the flame and diffuses the heat, so the glass warms across its whole base instead of at one hot spot, which greatly reduces the risk of cracking. It also gives small vessels a flat, stable platform that stops them tipping or slipping through the tripod ring. Typical jobs include boiling water for the starch-in-leaf test, heating a solution until crystals start to form and dissolving agar for a culture medium.

Centre the vessel over the ceramic circle and never heat empty glassware. Iron stays hot long after the flame is turned off, so leave the gauze to cool on the tripod before moving it. Store it dry to limit rusting and replace it once the ceramic centre cracks or flakes. Most schools order one gauze for every tripod stand so each bench has a complete heating station.

OEM Manufacturer

ScienceLab is the trading name of Jain Scientific Equipments Private Limited, the OEM (original equipment manufacturer) of this wire gauze. Each gauze is made at the company's own factory in Ambala, Haryana, India and supplied factory-direct to schools, colleges, institutions, dealers and importers, so replacement gauzes and repeat bench sets are handled by the manufacturer itself — just ask us. Production takes place at the company's licensed factory at 449, HSIIDC Industrial Area, Saha, Ambala (Factory Licence AMB-ONLINE-CHD-J-414), and the company is incorporated under CIN U29309HR2020PTC087597. See our company profile for more.

Related Biology Lab

The rest of a standard heating set-up:

More apparatus is available in the Biology Lab category.

Frequently Asked Questions

Is the Wire Gauze a tool for measuring wire thickness?
No. The Wire Gauze (SCL357/078) is a heating gauze that sits on a tripod under glassware. It spreads the flame's heat; it is not a gauge for measuring the diameter of wire.

What size is the Wire Gauze?
The Wire Gauze is listed as 6" dia and is square in shape. If it must fit a particular tripod ring or bench set-up, contact us to confirm the dimensions before placing your order.

What does the ceramic centre of the Wire Gauze do?
The ceramic circle in the centre of the Wire Gauze spreads the burner flame's heat across the base of the beaker or flask, so the glass warms evenly and is not exposed to one concentrated hot spot.

How should the Wire Gauze be cared for?
Let the Wire Gauze cool on the tripod after heating, because iron holds heat for a long time. Store it dry to limit rusting, and replace it once the ceramic centre cracks or flakes away.

Who manufactures the Wire Gauze?
The Wire Gauze is manufactured by Jain Scientific Equipments Pvt Ltd (ScienceLab), the OEM, at its own licensed factory at Saha, Ambala, Haryana, India. Schools, dealers and importers receive it factory-direct, with quotations issued by the manufacturer.

Can you supply Wire Gauzes for a whole lab or for export?
Yes. Send code SCL357/078, the number of Wire Gauzes and the delivery destination; ScienceLab quotes directly as the maker for schools, colleges, dealers and importers in India and international markets.

Request a Quote

To price the Wire Gauze, reach us through the contact page or add it to the enquiry cart together with tripods and burners for each bench; the quotation comes direct from the manufacturer.

Last updated: 16 November 2026

Acetic Acid Glacial (AR Grade)

Product Code : “SCL358/079”

Acetic Acid Glacial (AR Grade) is glacial, undiluted acetic acid of analytical reagent grade, in a 500 ml pack supplied with an MSDS. Biology labs use it to fix and stain cells, for example in the onion root-tip mitosis squash, where it goes into acetic-alcohol fixative and forms the acid base of acetocarmine and aceto-orcein stains.

Acetic acid pack and grade as listed

ParameterDetail
ProductAcetic Acid Glacial (AR Grade)
FormGlacial (undiluted) acetic acid
Pack size500 ml
GradeAnalytical reagent (AR)
DocumentationSupplied with MSDS
Product codeSCL358/079
Minimum order10 units
DispatchUsually within 7 to 10 working days
Supplied byScienceLab (Jain Scientific Equipments Pvt Ltd), Ambala, India

Root-tip and weak-acid practicals with acetic acid

Fixing onion root tips. Stand an onion over water until fresh roots appear, cut the tips in the morning and drop them straight into an acetic-alcohol fixative made up as the practical manual directs. Keep them in a covered watch glass or a labelled tube for the time the manual gives.

Onion and garlic tips side by side. Fix garlic root tips in the same way as onion tips, then stain one tip of each in acetocarmine. Squash each on a plain slide under a coverslip, and let students compare how clearly the chromosomes show, checking the stages they find against a prepared onion root tip slide.

Weak-acid tests. In chemistry periods, staff dilute the acid as the manual directs, and students try the dilute solution on blue litmus paper, on a few granules of calcium carbonate and on a short strip of magnesium ribbon in separate tubes. Running the same tests with dilute hydrochloric acid shows how much more gently a weak acid reacts.

Handling acetic acid on the bench

Read the MSDS before the first class. Wear safety goggles and gloves, pour in a fume cupboard or a well-ventilated room, and when making any dilution add the acid to the water, never the water to the acid. Label each new bottle with its contents and the date, close the container tightly after use, and keep it away from heat, flames and oxidising chemicals.

Frequently Asked Questions About the Acetic Acid Glacial (AR Grade)

What does the acetic-alcohol fixative do to root tips?

It kills the cells quickly and holds each chromosome at the stage of division it had reached, so the squash shows a true picture of the dividing tissue. Leave the tips in the fixative for the period your manual gives, then move them to fresh alcohol if they are to be kept for a later class.

When should onion root tips be cut for a mitosis slide?

Grow the roots in water first and cut the tips in the morning, when more cells in onion roots are dividing. Take only the last few millimetres, where the dividing zone lies, and put them into the fixative at once so that division stops where it is.

Why does acetocarmine contain acetic acid?

Acetocarmine is carmine dye dissolved in acetic acid. The acid carries the dye into the cells, fixes the chromatin as the stain works, and leaves the cytoplasm pale, so the chromosomes stand out against a light background. Aceto-orcein relies on the same acid base with a different dye.

Where should this acid be kept in the lab store?

Keep the closed bottle in an acid cupboard in a cool, ventilated store. Hold it apart from oxidising acids such as nitric acid and from bases such as sodium hydroxide, and well away from heat and open flames. The storage section of the supplied MSDS gives the conditions for this product.

What should be checked on the label and MSDS before a practical?

Check that the bottle label matches the product named in the practical, then read the MSDS sections on hazards, first aid and spills. Set out goggles, gloves and water for rinsing before students start, and make sure every bottle or beaker of prepared solution carries its own label.

How should leftover fixative and stain be disposed of?

Collect used fixative and stain in a labelled waste container kept for that purpose, and never mix it with oxidisers or bases. Follow the disposal section of the MSDS and your institution's chemical waste rules. Rinse slides and watch glasses with water before washing them.

Reagents and glassware for a root-tip squash

To request a quotation, send the product name, code and quantity through our contact page or add the item to your enquiry cart.

Last updated: 15 November 2026

Acetone (AR Grade)

Product Code : SCL359/080

Acetone (AR Grade) is a fast-evaporating organic solvent in a 500 ml pack, supplied with an MSDS. Biology classes use it to extract chlorophyll and other leaf pigments and then run paper chromatography on the extract. It also serves as a final rinse that strips grease and marker ink from washed glassware and helps it dry quickly.

Acetone grade and pack

ParameterDetail
ProductAcetone (AR Grade)
Pack size500 ml
GradeAnalytical reagent (AR)
DocumentationSupplied with MSDS
Product codeSCL359/080
Minimum order10 units
DispatchUsually within 7 to 10 working days
Supplied byScienceLab (Jain Scientific Equipments Pvt Ltd), Ambala, India

Leaf pigment practicals with acetone

Making the leaf extract. Tear fresh green leaves into a pestle and mortar, add a little clean sand and a small volume of acetone, and grind until the liquid turns deep green. Filter it through Whatman's filter paper in a glass funnel to hold back the leaf fragments, and cap the extract at once.

Running the chromatogram. Draw a pencil line across a strip cut from chromatography paper and build up a small, dark spot of extract on it, letting each drop dry before the next. Stand the strip in a covered glass beaker holding a shallow layer of the developing solvent named in the manual. Carotene, xanthophylls and the chlorophylls climb to different heights as distinct coloured bands.

Rinsing glassware. After washing and a water rinse, a small splash of acetone swirled round a beaker or test tube lifts the last grease and marker ink and carries the water away, so the glass dries within minutes. Collect the rinsings in a labelled solvent waste bottle instead of pouring them down the sink.

Flames, ventilation and containers for acetone

Acetone is highly flammable and its vapour spreads easily. Put out every flame, spirit lamps and burners included, before a bottle is opened, and work in a ventilated room. Wear goggles and gloves, since it dries the skin. Replace the cap straight after pouring, decant it only into glass because it attacks many plastics, and store the closed bottle in a cool place away from heat.

Frequently Asked Questions About the Acetone (AR Grade)

Why must every flame be out while acetone is in use?

Acetone is highly flammable and gives off vapour even at room temperature. The vapour is heavier than air, so it can creep along a bench and reach a spirit lamp or burner some distance away. Turn off all flames and hot surfaces first, then open the bottle in a ventilated room.

What protection do students need when handling acetone?

Goggles protect the eyes from splashes, and gloves stop the solvent stripping the natural oils from the skin, which leaves it dry and cracked. Acetone softens some glove materials, so change gloves that become soaked. Wash any splash off the skin with water, and rinse eyes at once if they are splashed.

How should a spill or used acetone be dealt with?

For a spill, put out any flames, open windows and soak up the liquid with absorbent paper, leaving the paper to dry in a fume cupboard away from ignition sources. Collect used acetone and rinsings in a labelled, capped solvent waste bottle and dispose of it under your institution's chemical waste rules.

Why is the chromatography container kept covered?

A cover lets solvent vapour fill the air inside, so the solvent does not evaporate from the paper as it climbs and the front rises evenly. Without it, bands can stop short or spread. Covering also keeps solvent vapour out of the room.

Why is the origin line drawn in pencil and kept above the solvent?

Graphite does not dissolve in the solvent, but ink would run up the paper and mix its own dyes with the leaf pigments. The solvent level must sit below the line. If the spot dips under the surface, the pigments wash out into the solvent instead of climbing the paper.

Why do the leaf pigments separate into bands?

Each pigment has its own balance between how well it dissolves in the moving solvent and how strongly it clings to the paper. Orange-yellow carotene usually travels furthest, followed by yellow xanthophylls, blue-green chlorophyll a and yellow-green chlorophyll b. Divide the distance each band moved by the distance the solvent front moved to get its Rf value.

Apparatus and solvents for leaf pigment chromatography

Supplier

This AR grade acetone is supplied by ScienceLab, the trading name of Jain Scientific Equipments Pvt Ltd in Ambala, Haryana. Alongside it, ScienceLab supplies the pestle and mortar, chromatography paper and glass beakers that a leaf pigment practical needs, so one enquiry can cover the whole set. Its laboratory supplies reach schools, colleges and training labs in 110 countries. See the ScienceLab company profile.

To request a quotation, send the product name, code and quantity through our contact page or add the item to your enquiry cart.

Last updated: 15 November 2026

Agar Block

Product Code : SCL360/081

Agar Block is a 500 gm pack of agar, the seaweed-derived gelling agent that sets culture media, diffusion blocks and plain gels in biology and microbiology practicals. It is listed as analytical reagent grade and comes with an MSDS. Agar is a gelling agent only, so nutrients must be added before it will grow microbes.

Agar pack and grade as listed

ParameterDetail
ProductAgar Block
MaterialAgar, a seaweed-derived gelling agent
Pack size500 gm
Grade (as listed)Analytical reagent
DocumentationSupplied with MSDS
Product codeSCL360/081
Minimum order10 units
DispatchUsually within 7 to 10 working days
Supplied byScienceLab (Jain Scientific Equipments Pvt Ltd), Ambala, India

Gels, plates and diffusion cubes from agar

Preparing a gel. Weigh the agar, sprinkle it into distilled water in a flat bottom flask while stirring, and heat it on a hot plate until the liquid turns completely clear. Let it cool until the flask can be held, then pour it into glass petri dishes and leave them undisturbed to set. For culture plates, add the nutrients the practical names before heating, and sterilise the flask of medium and the dishes, for example in an autoclave, before the plates are poured.

Diffusion cubes. Make the gel with a few drops of phenolphthalein and a little sodium hydroxide so that it sets pink. Cut cubes of three sizes with a scalpel, drop each into dilute hydrochloric acid, and use a digital stopwatch to time how long each cube takes to turn colourless right through.

Growth substances from shoot tips. Cut the tips from young oat or maize coleoptiles and stand them on small agar blocks for a few hours. A block set on one side of a coleoptile whose tip has been removed makes the shoot bend away from that side, showing that a growth substance passed from the tip into the agar.

Storing and handling agar

Keep the pack tightly closed in a cool, dry place, because agar draws moisture from the air. Read the MSDS before first use. Molten agar holds its heat for a long time, so lift the hot flask with a cloth or heat-resistant gloves and pour slowly, away from your body.

Frequently Asked Questions About the Agar Block

Why has the agar not set after cooling?

Usually the agar never fully dissolved. It needs boiling with steady stirring until the liquid is completely clear, and a cloudy mixture sets soft or not at all. Too little agar for the volume of water, or long heating with an acid in the mix, also gives a weak gel. Weigh carefully and keep stirring while it heats.

Why should molten agar cool a little before it is poured?

Very hot agar steams heavily, and the water condenses on the lid and drips back onto the gel. Pour once the flask can be held, keep the lids on while the plates set, and then store them upside down so that any drops collect on the lid instead of the surface.

How much agar should go into each dish?

Pour enough to cover the base in an even layer a few millimetres deep, tilting the dish gently to spread it. A very thin layer dries out and cracks during incubation, while a thick one wastes agar and takes longer to set. Pour every plate of a practical to the same depth.

Why do smaller agar cubes lose their colour sooner?

Acid enters each cube through its surface, and a small cube has more surface for its volume and a shorter path to the centre. Work out surface area divided by volume for each size: the ratio rises as cubes get smaller. This is why large organisms need exchange surfaces and transport systems.

What makes the results of a cube diffusion test unreliable?

Uneven cutting is the main error, so measure each cube and trim it square. Use agar from one batch so the indicator strength is the same, keep the acid volume, concentration and temperature constant, and agree in advance what counts as colourless. Repeat each size and work out a mean time.

Can the Agar Block be used on its own as a culture medium?

No. Agar only sets the medium into a gel and provides almost no food for microbes. For culture plates, dissolve the nutrients named in your practical with the agar before pouring. Plain agar gels are used for diffusion work and plant growth experiments.

Glassware, heating and reagents for agar gels and plates

To request a quotation, send the product name, code and quantity through our contact page or add the item to your enquiry cart.

Last updated: 15 November 2026

Ammonium Oxalate

Product Code : SCL364/084

Ammonium Oxalate is a white crystalline salt, listed as an analytical reagent and packed in 500 gm with an MSDS. A few drops of its solution reveal calcium in a sample as a white precipitate of calcium oxalate. Microbiology classes also dissolve it with crystal violet to make the primary stain for the Gram method.

Ammonium oxalate grade and pack

ParameterDetail
ProductAmmonium Oxalate
FormWhite crystalline salt
Pack size500 gm
Grade (as listed)Analytical reagent
DocumentationSupplied with MSDS
Product codeSCL364/084
Minimum order10 units
DispatchUsually within 7 to 10 working days
Supplied byScienceLab (Jain Scientific Equipments Pvt Ltd), Ambala, India

Calcium tests and stain making with ammonium oxalate

Calcium in water samples. Pour equal depths of tap water, well water and distilled water into separate test tubes and add a few drops of ammonium oxalate solution to each. A white cloudiness marks calcium. Hold the tubes against a dark card and rank the samples by how cloudy they turn.

Calcium in milk whey. Stir a little dilute acetic acid into milk until the curd separates, then filter the whey through Whatman's filter paper in a glass funnel. Add the reagent to the clear filtrate. A white precipitate shows that calcium remains in the whey after the curd is taken out.

Group analysis for calcium. Dissolve the group carbonate precipitate in dilute acetic acid and split the solution into portions. Test one with potassium chromate for barium and another with ammonium sulfate for strontium. If both stay clear, add a little ammonium hydroxide and ammonium oxalate to the last portion, and look for a white precipitate.

Making Gram crystal violet. Dissolve crystal violet in ethanol, and separately dissolve ammonium oxalate in distilled water measured in a measuring cylinder. Mix the two solutions, let the mixture stand, filter it and keep the stain in an amber reagent bottle labelled with its name and date.

Frequently Asked Questions About the Ammonium Oxalate

Why is the calcium test done in acetic acid and not in hydrochloric acid?

Calcium oxalate does not dissolve in a weak acid such as dilute acetic acid, so the white precipitate can form and stay visible. Dilute hydrochloric acid and other strong acids dissolve it. A strongly acidic sample can therefore hide calcium, so add ammonia solution until it is neutral or faintly alkaline before testing.

Do barium and strontium also give a white precipitate with ammonium oxalate?

Yes. Their oxalates are also sparingly soluble, so a white precipitate on its own does not prove calcium. In the salt analysis scheme, barium is ruled out first with potassium chromate, which gives a yellow precipitate, and strontium with ammonium sulphate. Only then is a white oxalate precipitate read as calcium.

How is a calcium result confirmed after the oxalate test?

Use a flame test. Clean the wire in concentrated hydrochloric acid until it adds no colour to the flame, dip it in a paste of the salt with the acid and hold it in the edge of a non-luminous flame. Calcium gives a brick-red colour, while strontium gives a deeper crimson.

What does ammonium oxalate do in the crystal violet stain?

It keeps the stain stable. Crystal violet is dissolved in ethanol, ammonium oxalate is dissolved in distilled water, and the two are then mixed. With the oxalate present, less dye settles out of the solution on standing. Filter the mixed stain before use and store it in a dark, labelled bottle.

Why should the reagent be made up with distilled water?

Tap and well water often carry dissolved calcium, which reacts with the oxalate and clouds the reagent before it is used. Distilled water keeps the solution clear. Run a blank tube of distilled water and reagent beside the samples, so any cloudiness can be traced to the sample itself.

How should ammonium oxalate be handled in class?

It is harmful if swallowed and can irritate the skin and eyes. Wear gloves and goggles while weighing and dissolving it, avoid raising dust and wash hands afterwards. Keep the stock tightly closed in a dry cupboard away from food, label every prepared bottle and follow the supplied MSDS.

Glassware, water and reagents for calcium tests and stain making

To request a quotation, send the product name, code and quantity through our contact page or add the item to your enquiry cart.

Last updated: 15 November 2026

Ammonium Molybdate

Product Code : SCL367/085

Ammonium Molybdate is an analytical reagent in a 100 gm pack, supplied with an MSDS, for detecting phosphate in biology and chemistry practicals. Added to an acidified sample and warmed, it gives a canary-yellow precipitate when phosphate is present, so classes can test bone ash, plant ash, soil or fertiliser samples for phosphorus.

Ammonium molybdate grade and pack

ParameterDetail
ProductAmmonium Molybdate
GradeAnalytical reagent
Pack capacity100 gm
Safety documentationSupplied with MSDS (Material Safety Data Sheet)
Product codeSCL367/085
Minimum order10 units
DispatchUsually within 7 to 10 working days
Supplied byScienceLab (Jain Scientific Equipments Pvt Ltd), Ambala, India

Phosphate tests with ammonium molybdate

Phosphate in bone and plant ash. Heat a small piece of dry bone or some dried leaves in a crucible with lid until only pale ash remains, and let it cool. Dissolve part of the ash in dilute nitric acid that staff have prepared from concentrated nitric acid, then filter the solution into a clean test tube.

Running the test. Add an excess of ammonium molybdate solution, made up in distilled water shortly before the class, and warm the tube gently over a spirit lamp, holding it in a test tube holder. A canary-yellow precipitate confirms phosphate, while a tube that stays clear shows none was detected.

Controls and comparisons. Run a positive control with a little calcium phosphate dissolved in the same acid, and a blank of acid and distilled water only. Students then test soil and fertiliser extracts and rank them by how quickly and how heavily the yellow precipitate forms.

Handling the reagent and the acid

Read the MSDS before the class. Wear gloves and goggles, above all once nitric acid is in use, and leave the concentrated acid to staff. Weigh the reagent on a digital analytical balance, keep the container tightly closed in a cool, dry place, and collect used test solutions in a labelled waste container.

Frequently Asked Questions About the Ammonium Molybdate

Why must the sample be acidified with nitric acid?

The yellow phosphomolybdate forms only in acid solution, where the phosphate is present as phosphoric acid. In neutral or alkaline conditions no precipitate appears, even when phosphate is there. Nitric acid also dissolves the calcium phosphate in bone ash, bringing the phosphate into solution for the test.

What does the yellow precipitate tell students?

It is ammonium phosphomolybdate, a yellow salt that is insoluble in the acid mixture, so its appearance shows that phosphate was in the sample. It can form slowly in the cold, which is why the tube is warmed. A faint yellow tint with no solid is not a clear result, so compare it with the controls.

Why does the test sometimes turn blue instead of yellow?

Reducing substances in a sample, such as vitamin C in fresh plant juice or traces of organic matter, can reduce molybdate to an intense blue compound, and phosphate speeds this up. The blue colour is used in colorimetric phosphate methods, but the school test expects the yellow precipitate. Ashing samples first burns off the reducing matter.

Can anything other than phosphate give a yellow precipitate?

Yes. Arsenate forms a very similar yellow precipitate with acidified molybdate, especially on warming, and a few other ions can interfere. School samples such as bone, leaves and fertiliser rarely contain them, but the result is most reliable when read beside a known phosphate control.

Why run a positive control and a blank with the samples?

The positive control shows that the reagent and the warming step work. The blank of acid and distilled water shows the glassware and water are free of phosphate, since traces of phosphate detergent left in a tube can give a misleading yellow result. Only then can students draw a firm conclusion about each unknown.

Reagents and apparatus for the phosphate test

To request a quotation, send the product name, code and quantity through our contact page or add the item to your enquiry cart.

Last updated: 15 November 2026

Request A Catalogue

Request A Catalogue

Request our catalogue of educational and scientific lab equipment.

Request Now