Exhaust Gas Calorimeter

Product Code : SLE/MCE/54

Connected to a test engine by an exhaust gas hose, the Exhaust Gas Calorimeter finds how much heat the engine loses in its exhaust. Inside an insulated stainless steel tank, the gas passes through a counter-flow finned pipe heat exchanger. Four temperature sensors and a 0–160 L/h water flow meter feed digital displays through a measuring amplifier.

Finned counter-flow exhaust calorimeter specifications

ParameterDetail
Heat exchangerCounter-flow, finned pipe type, in an insulated stainless steel tank
Heat exchange area0.944 m² on the exhaust gas side; 0.141 m² on the water side
Exhaust gas temperature2 × 0–600 °C
Cooling water temperature2 × 0–200 °C
Water flow rate0–160 L/h (flow meter)
Instrumentation4 temperature sensors, flow meter, measuring amplifier with digital displays
Engine connectionExhaust gas hose
Power supply230 V, 50 Hz, single phase
Size and weight600 × 600 × 1300 mm; approx. 103 kg
Product codeSLE/MCE/54
Minimum order10 units
DispatchUsually within 7 to 10 working days
ManufacturerScienceLab (Jain Scientific Equipments Pvt Ltd), Ambala, India

Exhaust heat experiments with the finned calorimeter

Setting up at the engine. Run the exhaust gas hose from the four stroke four cylinder petrol engine test bench to the calorimeter inlet. Start the water and set a steady flow on the flow meter before any exhaust passes through, then hold it steady so the outlet water stays well below boiling.

Exhaust heat by two routes. From the water side, students find the heat taken up from flow, specific heat and temperature rise. From the gas side, they use fuel flow from a manual volumetric fuel gauge plus the air flow, and the gas temperature fall. The gap between the two answers opens a discussion of heat lost through the tank.

Exchanger performance. Using the stated gas-side area of 0.944 m², students work out the overall heat transfer coefficient from the heat transferred and the log mean temperature difference. Repeating this at two or three water flow rates shows how flow changes heat transfer.

Petrol against diesel exhaust. Run the same test on the 4 stroke diesel engine and compare gas inlet temperatures and the exhaust share of fuel energy with the petrol results.

Frequently Asked Questions About the Exhaust Gas Calorimeter

Why is the gas-side area so much larger than the water-side area?

Heat passes from a gas to metal far less readily than from metal to water. Fins add surface on the exhaust side, giving 0.944 m² against 0.141 m² on the water side, which makes up for much of that weaker gas-side transfer.

How is the exhaust gas mass flow found for the heat balance?

Add the mass of air the engine draws in per minute to the mass of fuel it burns per minute. Air flow usually comes from the engine's air intake measurement and fuel flow from timing a known volume of fuel. That total, multiplied by the exhaust specific heat and temperature difference, gives the exhaust heat.

Which specific heat should be used for the exhaust gas?

Many lab sheets assume a fixed value close to that of air. The calorimeter lets students check it: divide the heat taken up by the water by the gas mass flow and the fall in gas temperature across the exchanger. Comparing the two values is a good discussion point in the report.

Does soot on the fins change the results over time?

Yes. Soot and other deposits insulate the fins, so less heat reaches the water and the gas leaves hotter, and the effect grows with running hours. Record the gas outlet temperature at one reference load each term. A steady rise shows that the exchanger needs cleaning as the supplied operating instructions describe.

Why keep the cooling water running after the engine stops?

The tank and finned pipe stay hot after the exhaust stops. Without flow, water standing in the exchanger can overheat and boil. Leave the water running until the outlet water temperature has fallen close to the inlet temperature, then shut it off.

Where does the calorimeter result go in the heat balance sheet?

It supplies the line for heat carried away by the exhaust. Put every line, from fuel heat to brake power, jacket cooling water and exhaust, in the same units per minute and as a percentage of fuel heat. Whatever is left after these lines is the unaccounted heat.

Engine test and heat transfer equipment

To request a quotation, send the product name, code and quantity through our contact page or add the item to your enquiry cart.

Last updated: 14 November 2026

Request A Catalogue

Request A Cataloguer

Request our catalogue of educational and scientific lab equipment.

Request Now
Supply of Exhaust Gas Calorimeter from India to Finland, France, Tanzania, Thailand, Sri Lanka, Congo, Costa Rica, Ivory Coast, Croatia, Cuba, Cyprus, Czech Republic, Denmark, Djibouti, Dominica, Afghanistan, Albania, Algeria, Andorra, Angola, Antigua and Barbuda, Argentina, Armenia, Australia, Austria, Azerbaijan, Bahamas, Bahrain, Bangladesh, Barbados, United Arab Emirates (UAE, Dubai), United Kingdom (London), United States, Uruguay, Uzbekistan, Vanuatu, Belarus, Belgium, Belize, Benin, Bhutan, Bolivia, Bosnia and Herzegovina, Botswana, Brazil, Brunei, Bulgaria, Burkina Faso, Burma Myanmar, East Timor, Ecuador, Egypt, El Salvador, Equatorial Guinea, Eritrea, Estonia, Ethiopia (Addis Ababa), Fiji, Burundi, Cambodia, Cameroon, Canada, Cape Verde, Central African Republic, Chad, Chile, Colombia. Math Teaching Kit suppliers in Luxembourg, Macedonia, Madagascar, Malawi (Lilongwe), Malaysia (Kuala Lumpur), Maldives, Mali, Malta, Marshall Islands, Mauritania, Mexico, Micronesia, Moldova, Monaco, Mongolia, Montenegro, Morocco, Mozambique, Namibia, Comoros, Congo. Math Teaching Kit manufacturers in Dominican Republic, Gabon, Gambia, Georgia, Germany, Ghana, Greece, Grenada, Guatemala, Guinea, Guinea-Bissau, Guyana, Haiti, Honduras, Hungary, Iceland, Indonesia, Iran, Iraq, Niger, Nigeria (Abuja), Norway, Oman, Palau, Panama, Papua New Guinea, Paraguay, Peru, Philippines (Manila), Poland, Ireland, Israel, Italy, Jamaica, Japan, Jordan, Kazakhstan, Kenya (Nairobi), Kiribati, Korea, Kuwait, Kyrgyzstan, Laos, Latvia, Lebanon, Lesotho, Liberia, Liechtenstein, Lithuania, Mauritius, Nauru, Nepal, Netherlands, New Zealand, Nicaragua, Portugal, Qatar, Romania, Russia, Rwanda (Kigali). Math Teaching Kit exportets to Saint Kitts and Nevis, Saint Lucia, Saint Vincent and the Grenadines, Samoa, San Marino, Sao Tome and Principe, Saudi Arabia, Senegal, Serbia, Seychelles, Sierra Leone, Singapore, Slovakia, Slovenia, Solomon Islands, Somalia, South Africa, South Sudan, Spain, Sudan, Suriname, Swaziland, Sweden, Switzerland, Syria, Tajikistan, Togo, Tonga, Trinidad and Tobago, Tunisia, Turkey, Turkmenistan, Tuvalu, Uganda (Kampala), Ukraine, Venezuela, Vietnam, Yemen , Zambia (Lusaka), Zimbabwe