DESCRIPTION:
Infrared (IR) clinical thermometer, digital, handheld, minimmal range 34– 42 °C.
SPECIFICATIONS:
Infrared (IR) non-contact clinical thermometer
Factory calibrated and pre-set emissivity for all skin types
Measuring distance between 3 – 12 cm / 1.22 – 6 inch, depending on the model
Measurement of skin temperature trough thermal radiation detection
Digital display located at the proximal end (user side)
Handheld design with ergonomic pistol type grip or similar design.
Handgrip with index finger or thumb switch to trigger measurements
IR sensor located at the distal end (patient side)
Visual or audio alert on switch-on, ready-to-use and measurement completed.
Water spill proof and suitable to be cleaned and disinfected
Preferably backlit LCD display, suitable for reading in bright sunlight
Display visualisation of measured temperature, battery status ,operational status, errors including incorrect reading
Digital read-out, user-selectable, in Celsius or Fahrenheit scale
Graduation 0.1 °C / 0.3 °F
Accuracy 0.3 °C (minimum guaranteed)
Automatic switch-off when not in use
Low and high temperature visual or audiable alarms
Internal memory (the presence of this feature depends on the available model), to retain several readings
Battery powered, 2 x 1.5 V AA or AAA commercial batteries depending on the model..
Temperature measurement range 34 – 42 °C / 93 – 108 °F
Hold function, to keep the latest measurement visualised on the display
Contact Science Lab for your Educational School Science Lab Equipments. We are best geography lab equipments manufacturers, geography lab equipments suppliers, geography lab models suppliers, high school biology lab equipment india, high school biology lab equipment manufacturers, high school chemistry lab equipment manufacturers.
Technical Specifications:-
Sterile enteral feeding/aspirating catheter for single use.
Single channel tube.
Proximal end with cup connector, conical tip, allowing the tube to be connected to devices such as feeding syringes (catheter tip) or suction pump system.
Material: Polyvinyl chloride (PVC).
Size selected: Diameter CH12, length approximately 125cm
Disposable
Sterile
Initial sterilisation method: Ethylene oxide gas
Open distal end with four side windows.
Tube with markings at 40, 50, 60 and 70cm from the distal end.
Length expressed in cm.
Colour code/ external diameter: Visible on cup connector.
Weight/Volume/Dimensions:-
Estimated weight: 0.022kg
Estimated volume: 0.232cdm
Instructions for use:-
Sterile aspirating/feeding tube:
Device used for aspirating liquids and / or gases from stomach, duodenum and small intestine.
Device used for feeding child with feeding syringe conical tip
Marking on the tube: 40, 50, 60, 70cm from the distal end. Correspond to the following regions:
cardia, stomach, duodenum, jejunum.
The size has been chosen as being the most commonly used.
Contact Science Lab for your Educational School Science Lab Equipments. We are best high school maths lab kit manufacturers, high school physics lab equipment, high school science kits exporters, high school science lab equipment, high school science lab equipment manufacturers, high, school science lab equipments suppliers.
General Description:-
Syringe, feeding, 50ml, Luer tip, sterile
Technical Specifications:-
Syringe, 3-pieces: barrel, plunger and gasket
Capacity: 50ml or 60ml
Disposable
Sterile
Clear syringe barrel, precise graduation in ml for the volume dosage, permanent marking, easy readability
Centric or eccentric Luer tip
Safe plunger backstop
Initial sterilisation method: Ethylene oxide gas or Gamma radiation.
Weight/Volume/Dimensions:-
Estimated weight: 0.040kg
Estimated volume: 0.20cdm
Instructions for use:-
The sterile syringe 50/60ml Luer tip can be used for gastroenteral feeding, manual aspiration of liquids or gas from stomach, manual pharyngeal or tracheal aspiration/suction.
The size has been chosen as being the most commonly used
This syringe Luer tip is fitting feeding tubes with Luer tips
for feeding premature, newborn baby or malnourished infants.
Contact Science Lab for your Educational School Science Lab Equipments. We are best indian biology lab equipments, lab equipment exporters, lab equipments exporter, lab equipments manufacturers, lab instruments manufacturers, laboratory equipment dealer.
General Description:-
Syringe, feeding, 50ml, catheter tip, sterile
Technical Specifications:-
Syringe, 3-pieces: barrel, plunger and gasket.
Capacity: 50ml or 60ml
Disposable
Sterile
Initial sterilisation method: Ethylene oxide gas or Gamma radiation.
Clear syringe barrel, precise graduation in ml for the volume dosage, permanent marking, easy readability
Centric or eccentric catheter tip
Safe plunger backstop
Instructions for use:-
The sterile syringe 50/60ml catheter tip can be used for gastroenteral feeding, manual aspiration of liquids or gas from stomach, manual pharyngeal or tracheal aspiration/suction.
The size has been chosen as being the most commonly used.
Weight/Volume/Dimensions:-
Estimated weight: 0.040kg
Estimated volume: 0.300cdm
Contact Science Lab for your Educational School Science Lab Equipments. We are best laboratory equipments suppliers, laboratory glass equipments, math lab kits, mathematics lab equipment manufacturers, mathematics lab equipments, mathematics lab equipments manufacturers.
General Description-
Catheter, Foley, CH18, sterile, disposable
Technical Specifications :-
Urethral catheter with balloon: Foley catheter 2-way with nelaton tip.
Central channel for urinary drainage, straight rounded distal end with lateral eyes, proximal end with cup connector allowing catheter to be connected to urine bag.
Side channel for inflating balloon, ending by a non-return valve with Luer tip connector.
Diameter expressed in Charriere, French gauge.
Length expressed in cm.
Balloon capacity expressed in ml.
Colour code / external diameter visible on connector.
Material: Natural latex, silicone coated.
Balloon capacity: 5 – 15ml.
Single-use.
Sterile.
Size selected:
Diameter: CH18
Length: 30 - 40cm,
Initial sterilisation method: ethylene oxide gas.
Instructions for use-
Sterile urethral catheter with balloon, Foley catheter 2-way, designed to be introduced into the bladder cavity, to drain off urine, for medium /long term catheterization. When inserting a urethral catheter, use strict aseptic techniques.
If lubrication is necessary to help to introduce the catheter, the substance used must not cause physical or chemical alterations to the catheter. If necessary, use sterile water.
The balloon should be inflated with water or physiological saline.
Weight/Volume/Dimensions :-
Estimated weight: 0.030kg
Estimated volume: 0.237cdm
Contact Science Lab for your Educational School Science Lab Equipments. We are best mathematics lab equipments suppliers, mathematics lab kit, mathematics lab kits india, maths kits ,maths lab equipment manufacturers in india, maths lab equipment suppliers.
Technical Specifications-
Urethral catheter without balloon, nelaton tip.
Length expressed in cm.
Colour code cup connector.
Atraumatic, soft, rounded closed distal end with 2 lateral eyes, proximal end with cup connector allowing catheter to be connected with urine bag.
Diameter expressed in Charriere, French gauge.
Material: Polyvinyl chloride (PVC).
Size selected:
Diameter CH14,
Initial sterilization method: Ethylene oxide gas
Length: 30 - 40cm,
Single-use
Sterile.
Weight/Volume/Dimensions-
Estimated weight: 0.012kg
Estimated volume: 0.128cdm
Instructions for use-
Sterile urethral catheter without balloon, nelaton tip, designed to be introduced into the bladder cavity, to drain off urine, for short term catheterization. When inserting a urethral catheter, use strict aseptic techniques.
If lubrication is necessary to help to introduce the catheter, the substance used must not cause physical or chemical alterations to the catheter. If necessary, use sterile water.
Contact Science Lab for your Educational School Science Lab Equipments. We are best maths lab equipments manufacturers, maths lab kit india, maths lab kit suppliers, maths lab kits manufacturers, metal testing equipments, physics lab educational equipmentss.
DESCRIPTION:
Robust shock resistant design allow use in demanding environments
Suitable for professional clinical use, all patient categories neonate, infant, adult
Ultra-compact pulse oximeter integrated into finger/toe clip
Accommodates finger/toe thicknesses 8 to 25mm directly or through the use of a separate sensor which can be connected to the device.
Spot-check of arterial blood oxygen saturation (SpO2) and heart rate(HR)
Measuring ranges:
SpO2 accuracy within: +/-3%
Pulse rate detection: 30 to 240 bpm
Pulse rate resolution: 1 bpm)
SpO2 detection within the range of: 70 to 99%
Pulse rate accuracy: within: +/-3%
Display shows SpO2, pulse rate, signal strength, sensor error or disconnect and low battery.
SpO2 resolution: 1% or less
Enclosure protection or better
Suitable for cleaning and disinfection with hospital-grade cleaning products.v
Batteries must allow at least 2500 spot-checks, calculated at 30 seconds per spot-check, or at least 21 hours of operation.
The unit is equipped with an automatic power off feature.
Power requirements two 1.5V AAA batteries
INSTRUCTIONS FOR USE
Pulse oximeter must be used and maintained properly according manufacturer's instructions.
For spot-check of percentage arterial oxygen saturation (SpO2, %) and pulse rate (HR, bpm) of all patient categories. Non-invasive monitor using a clip-on sensor placed on a finger or toe. The spot-check pulse oximeter is ultra-compact and fits easily pocket or carry-on bag.
ENVIRONMENTAL CONDITIONS
Storage conditions temperature: -20 °C to 60°C / RH: 10% - 95%
Operating conditions temperature: 5 to 40°C / RH: 30 to 80%
Contact Science Lab for your Educational School Science Lab Equipments. We are best technical educational equipments manufacturers, technical educational equipments manufacturer, technical educational equipments supplier, technical educational instruments, technical educational instruments exporter, technical educational instruments manufacturer, vocational training lab instruments exporter
General Description:-
Compress, gauze, 10 x 10cm, sterile, pack of 5.
Technical Specifications:-
Gauze compress, surgical folding, i.e. so that there are no free threads apparent after folding or when the first outside fold is opened. Non-detectable by X-ray.
Components: Bleached, purified textile, plain weave.
Material: Absorbent gauze, 100% cotton.
Size selected: Compress, gauze, folded.
Width: approximately 10cm.
Length: approximately 10cm
Disposable.
Thread count warp 95 to 105 threads/dm;
Weft 66 to 74 threads/dm
Weight: Approximately 23g/m2.
Type of gauze: 17 threads/cm2 (grammage 23g/m2).
Number of folds (thickness): 12.
Sterile.
Initial sterilisation method: Ethylene oxide gas or ionising radiation.
Instructions for use:-
Dressing material used for cleaning wounds, disinfecting healthy skin, protecting wounds, etc.
Weight/Volume/Dimensions:-
Estimated weight: 0.020kg
Estimated volume: 0.040cdm
Contact Science Lab for your Educational School Science Lab Equipments. We are best technical educational instruments supplier, technical institute lab equipments, technical lab equipments manufacturers, top lab equipments manufacturers, tvet lab equipment manufactruers, vocational training lab equipments exporter, vocational training lab equipments manufacturers.