The Precision Balance comes in 0.1 kg, 0.2 kg, 0.3 kg and 2 kg capacities, reading to 0.001 g or 0.01 g depending on the model. It has 2,00,000 internal resolutions, a backlit LCD, an RS 232 interface and an in-built rechargeable battery, and it calibrates automatically with an external weight.
| Parameter | Detail |
|---|---|
| Capacity options | 0.1 kg, 0.2 kg, 0.3 kg, 2 kg |
| Readability | 0.001 g or 0.01 g (by model) |
| Repeatability / linearity | ± 0.001 g or ± 0.01 g / ± 0.002 g or ± 0.02 g |
| Internal resolution | 2,00,000 |
| Pan size | 80 mm or 180 x 170 mm, stainless steel |
| Calibration, response and tare | Automatic with external weight; response time 3–4 seconds; full tare range |
| Display and functions | LCD with backlight; auto zero tracking, multifunction weighing units, level indicator, adjustable fit |
| Interface, power and protection | RS 232 available; in-built rechargeable battery with low battery indicator; overload protection design |
| Operating temperature, size and weight | 10°C to 40°C; 316 x 210 x 308 mm; approx. 6 kg |
| Product code | SLE/LB/13 |
| Minimum order | 10 units |
| Dispatch | Usually within 7 to 10 working days |
| Supplied by | ScienceLab (Jain Scientific Equipments Pvt Ltd), Ambala, India |
Checking a pipette by weighing. Weigh a dry, stoppered conical flask on a milligram model. Deliver water into it from a pipette, weigh again and note the water temperature with a laboratory thermometer. Divide the mass of water by its density at that temperature to find the volume the pipette really delivers, and repeat several times.
Ash content of dried leaves. Heat an empty crucible with lid to constant mass and weigh it. Add finely ground dry leaf and weigh again, then heat strongly until only grey ash remains. Cool, weigh, and express the ash mass as a percentage of the leaf mass.
Moisture in grain or flour. On a 0.01 g model, weigh a glass petri dish holding a thin, level layer of sample. Dry it in a laboratory oven, let it cool and weigh again, repeating until two readings agree. The loss in mass is the water the sample held.
A balance spreads its capacity across a limited number of display steps, so a larger capacity means larger steps. As a rule, the 0.001 g reading goes with the smaller capacities and the 0.01 g reading with heavier work. The pairing is set by model, so check it for the model chosen.
Switch it on with the pan empty and let it warm up for the time the supplied operating instructions give. Then check the level indicator and calibrate. During weighing, wait for the reading to settle before recording; the listed response time is 3–4 seconds.
Pan size goes with the model. The 80 mm pan suits weighing boats, papers and small vials for milligram work, and a small pan is less disturbed by moving air. The 180 x 170 mm pan takes beakers, trays and larger sample containers. Both are stainless steel and wipe clean.
The density of water changes with temperature, so the same mass of water takes up a slightly different volume when it is warmer or cooler. Look up the density at the measured temperature and divide the mass of water by it to get the delivered volume.
Most of the spread comes from technique: reading the mark at an angle, draining the tip differently each time, or warming the pipette with the hand. Draughts and evaporation from an open flask also move the third decimal. Practise the technique, stopper the flask and repeat.
Yes. Calibration runs automatically but needs an external weight, and that weight is not listed as part of the supply. Keep a weight of the value the model asks for beside the balance, stored in its own case so it stays clean.
To request a quotation, send the product name, code and quantity through our contact page or add the item to your enquiry cart.