The Seed Counter is a microcontroller-based electronic counter that delivers seeds in exact, programmed lots. The operator keys the required number into a membrane keyboard, sets an adjustable knob so the seeds move in a single row, and starts the run with one button. It handles seeds from 1 to 15 mm and counts up to 999999 in a lot.
| Parameter | Detail |
|---|---|
| Type | Electronic seed counter with programmed tallying |
| Control | Microcontroller based |
| Keyboard | Membrane keyboard |
| Maximum count | Up to 999999 seeds in a lot |
| Seed size range | 1 to 15 mm |
| Seed alignment | Adjustable knob keeps the seeds in a single row |
| Count control | Slow start and slow stop |
| Product code | SLE/AG/15 |
| Minimum order | 10 units |
| Dispatch | Usually within 7 to 10 working days |
| Supplied by | ScienceLab (Jain Scientific Equipments Pvt Ltd), Ambala, India |
Germination test. Program the counter for the number of seeds in one replicate and count four equal lots from the same sample. Lay them on moist paper in Petri dishes, hold them in a laboratory incubator and count the normal seedlings at the end of the test period.
Thousand-seed weight. Count several lots of one thousand seeds, weigh each lot and take the mean. Read the moisture of the same sample on the Digital Moisture Meter at the same time, because seed weight rises and falls with its water content.
Respiration in germinating seeds. Count two identical lots for the seed respiration kit and boil one as the control. Any difference in gas given off then comes from the living seeds and not from unequal seed numbers.
Sowing trials and packeting. Prepare counted lots for each plot or row of a field trial, so that plant stands can be compared fairly. The same routine fills seed packets with a fixed number of seeds.
Usually two seeds passed the counting point side by side, or dust and chaff were counted as seeds. Reset the knob so the seeds travel in a single row, clean the sample before pouring it in, and let slow stop finish the lot before you remove the container.
On a firm, level bench away from direct sunlight, damp and dust. A table that shakes or tilts breaks up the single row of seeds and can upset the count. Cover the counter when it is not in use.
Program a lot of one thousand seeds, weigh it on a laboratory balance and repeat for several replicate lots. The mean is the thousand-seed weight, which is used to set sowing rates and to express germination results per unit weight of seed.
Several equal lots from one sample let you check whether the results agree. If one replicate differs sharply from the rest, the sample was poorly mixed or test conditions varied, and the test should be repeated. The counter prepares equal lots in minutes.
Empty every seed left from the previous lot, then reset the adjustable knob for the new size within the 1 to 15 mm range. Run a short trial lot and count it by hand to confirm the setting before preparing test lots.
Switch off and unplug first. Brush out dust, husk and broken seed from the feed path and the counting point, and wipe the outside with a dry cloth. Dust left inside can be registered as seeds and spoil the next count.
To request a quotation, send the product name, code and quantity through our contact page or add the item to your enquiry cart.
Last updated: 14 November 2026