High Performance Liquid Chromatography (HPLC) (Product Code: SCI-303/06) is a fully automated preparative liquid chromatography system used to separate, detect and collect compounds from mixtures in pharmaceutical, analytical and research laboratories. It runs a quaternary gradient at 0.5 to 10 ml/min with UV or diode-array detection, and its fraction collector allows purification at micro, analytical or preparative scale. It is supplied by Jain Scientific Equipments Pvt Ltd (ScienceLab), Ambala, India, among its analytical lab instruments for India and international markets.
| Parameter | Detail |
|---|---|
| System type | Fully automated preparative system with PC control, detection and collection |
| Pump and mode | Quaternary system, gradient mode, 4 eluents |
| Flow rate | 0.5 to 10 ml/min |
| Operating pressure | High-range operation at 200 bar |
| Purification scale | Micro, analytical or preparative |
| Solvent positions | 24 aqueous buffers, or 12 aqueous buffers and 12 organic modifiers |
| Flow accuracy | < 2% |
| Flow precision | ± 0.1% RSD |
| Composition range | 0 to 100% |
| Composition accuracy | ± 0.5% (stated as independent of back pressure) |
| Detection | UV monitor; diode-array based or UV detector |
| Injection | 4-way injection/purge device |
| Cartridges | 12 mm cartridge adapter set; 1 x 12 mm and 1 x 40 mm pre-packed cartridges |
| Flow-path components | Back pressure regulator; waste diverter valve |
| Fraction collection | Fraction collector; 4 collection racks for a minimum of 30 tubes; 100 x 50 ml tubes compatible with the racks |
| Software and automation | Control unit with control software; network data processing; automatic flushing and column equilibration; sequence generation; set-ups for multiple samples and injections; settings stored as reusable templates; auto-stat and equilibrium programming; multi-method programming with external events |
| Workstation | Chromatography table with integrated monitor holder; compact design |
| Product code | SCI-303/06 |
| Supplied by | Jain Scientific Equipments Pvt Ltd (ScienceLab), Ambala, India |
HPLC separates the dissolved components of a mixture by pumping a changing blend of solvents through a packed cartridge; each component leaves at its own retention time and is picked up by the UV or diode-array detector. Because this configuration adds a fraction collector, it can also isolate purified portions of a compound, which suits drug development, natural-product isolation, method development and postgraduate teaching in laboratory analytical work.
Filter and degas solvents and buffers before use, and let the automatic flushing and equilibration finish before a sequence starts. Save methods that work as templates so later batches run the same way. At the end of the day, flush buffer salts out of the flow path so they cannot crystallise in the system.
ScienceLab is the trading name of Jain Scientific Equipments Private Limited, which supplies this HPLC system from Ambala, Haryana, to pharmaceutical companies, universities, research institutes, dealers and importers. We prepare the quotation, coordinate the configuration you choose and arrange packing and shipment. Learn more on our company profile.
Items that support chromatography teaching and sample preparation:
See more instruments in our Laboratory Equipment category.
What flow rate and pressure does the HPLC system handle?
The High Performance Liquid Chromatography (HPLC) system (SCI-303/06) delivers 0.5 to 10 ml/min in gradient mode and is listed for high-range operation at 200 bar, with flow accuracy of less than 2% and flow precision of ± 0.1% RSD.
Which detectors are available for the HPLC system?
The HPLC system is listed with a UV monitor and can be configured with a diode-array based or UV detector. Tell us the compounds you analyse and we will confirm the detector option and wavelengths in your quotation.
Can the HPLC system collect purified fractions?
Yes. This HPLC system is a preparative configuration with a fraction collector, 4 collection racks for a minimum of 30 tubes and 100 tubes of 50 ml, plus a waste diverter valve that sends unwanted eluent to waste instead of the collection tubes.
How many solvents can the HPLC system blend?
The quaternary HPLC system handles 4 eluents with a composition range of 0 to 100% and composition accuracy of ± 0.5%. Solvent positions allow 24 aqueous buffers, or 12 aqueous buffers and 12 organic modifiers, for flexible method development.
Who supplies the HPLC system?
The High Performance Liquid Chromatography (HPLC) system is supplied by Jain Scientific Equipments Pvt Ltd (ScienceLab), Ambala, Haryana, India. Ask us which make and model is currently offered, together with its software version and support arrangements.
Is a calibration certificate available for the HPLC system?
Availability of a calibration certificate or other validation documents for the HPLC system should be discussed with us before ordering, since it depends on the model quoted. Mention it in your enquiry through our contact page.
What does an HPLC quotation need?
For an HPLC quotation, state your preferred detector, the purification scale, spare cartridges and collection tubes required, the number of systems and the delivery destination in India or abroad. Send the details through the enquiry cart or contact page.
Ask for a quotation for the HPLC system (SCI-303/06) through our contact page, or add it to the enquiry cart with other laboratory items. Please include your application and detector preference so we can quote the right configuration.
Last updated: 24 September 2026