Centrifuge, Clinical, Swing Out Head (Product Code: SLE/LC/12) is a multi-purpose programmable centrifuge used to spin samples in medical, clinical, cytology, chemistry, pharmacy and biotechnology laboratories. Supplied with a swing out head rotor (maximum 4000 rpm), it holds up to 4 x 100 mL, identifies rotors automatically and stores 9 routine procedures, making it versatile pharmacy lab equipment in India as well as a clinical centrifuge. It is supplied by Jain Scientific Equipments Pvt Ltd (ScienceLab), Ambala, India.
| Parameter | Detail |
|---|---|
| Rotor included | Swing out head rotor, max 4000 rpm |
| Speed range | 300–6000 rpm (dependent on rotor type) |
| Maximum capacity | 4 x 100 mL |
| Maximum RCF | 4300 x g |
| Speed accuracy | ±20 rpm |
| Rotor compatibility | 9 rotor types; automatic rotor identification |
| Accessory range | Swing-out and fixed-angle rotors |
| Program memory | 9 routine procedures |
| Acceleration / braking | 9 acceleration and 10 brake settings; acceleration/braking time 9 s up / 10 s down |
| Run time | 30 secs to 99 mins, or continuous |
| Motor | Brushless DC, maintenance-free |
| Display | LCD with Speed/RCF switch |
| Safety devices | Door (autolocking lid), imbalance (IMB), motor temperature, rotor speed, chamber temperature |
| Power | 220/240 V, 50/60 Hz, 6.3 A |
| Dimensions | 445 x 579 x 269 mm |
| Weight | 36 kg |
| Product code | SLE/LC/12 |
| Supplied by | Jain Scientific Equipments Pvt Ltd (ScienceLab), Ambala, India |
The swing out buckets carry tubes out towards the horizontal as the rotor spins, giving a flat, well-defined sediment that suits cytology preparations, urine sediment, blood fractionation and other layered separations. With the included head limited to 4000 rpm and other rotor types able to take the system up to 6000 rpm, one instrument can cover gentle clinical spins as well as harder chemistry or pharmacy separations.
Store routine procedures in the 9 program memories so staff recall a method instead of re-entering it for every run, and use the acceleration and brake settings for soft starts and stops when layers are delicate. The Speed/RCF switch displays whichever value your method specifies. Allow for the 36 kg weight and the 445 x 579 x 269 mm footprint when planning bench space; biotechnology groups also use it as cell biology equipment for harvesting cells from larger tubes.
Jain Scientific Equipments Private Limited, the Ambala, Haryana company behind the ScienceLab name, supplies this centrifuge and its optional rotors to clinical, pharmacy, research and teaching laboratories and to dealers in India and international markets. Tender and institutional buyers who need vendor details can use GSTIN 06AAECJ8618A1ZT and LEI 3358004HRD1JIVXKYX49. Background on the business is in our company profile.
Rotors, tubes and alternatives for multi-format centrifugation:
See every model in the Centrifuges category.
Which rotor is supplied with the Centrifuge, Clinical, Swing Out Head?
The Centrifuge, Clinical, Swing Out Head is supplied with a swing out head rotor rated to a maximum of 4000 rpm. Other swing-out and fixed-angle rotors are available as accessories, and the centrifuge identifies the fitted rotor automatically.
Why is a 300–6000 rpm range quoted for the Centrifuge, Clinical, Swing Out Head?
The 300–6000 rpm range of the Centrifuge, Clinical, Swing Out Head depends on rotor type. With the included swing out head, 4000 rpm is the limit; higher speeds apply only to rotors rated for them. The maximum RCF is listed as 4300 x g.
Can a fixed-angle rotor be added to the Centrifuge, Clinical, Swing Out Head later?
Yes, the accessory range for the Centrifuge, Clinical, Swing Out Head includes swing-out and fixed-angle rotors, with 9 rotor types listed. Contact us to confirm which rotor, such as our Fixed Angle Rotor, suits your tubes and this model.
What does the program memory of the Centrifuge, Clinical, Swing Out Head store?
The Centrifuge, Clinical, Swing Out Head stores up to 9 routine procedures, so staff can recall a method instead of re-entering speed, time and acceleration settings for every run, which simplifies repeated work and reduces set-up errors.
What electrical supply does the Centrifuge, Clinical, Swing Out Head need?
The Centrifuge, Clinical, Swing Out Head runs on 220/240 V, 50/60 Hz at 6.3 A. Allow bench space for its 445 x 579 x 269 mm footprint and 36 kg weight when planning where it will be installed.
Which safety devices are fitted to the Centrifuge, Clinical, Swing Out Head?
The Centrifuge, Clinical, Swing Out Head has an autolocking lid (door), imbalance detection (IMB), and monitoring of motor temperature, rotor speed and chamber temperature, as listed in its technical specifications.
Who supplies the Centrifuge, Clinical, Swing Out Head?
The Centrifuge, Clinical, Swing Out Head is supplied by Jain Scientific Equipments Pvt Ltd (ScienceLab), Ambala, Haryana, India. The company quotes it with any extra rotors for institutions, dealers and importers in India and international markets.
Is a calibration certificate available for the Centrifuge, Clinical, Swing Out Head?
Availability of a calibration certificate for the Centrifuge, Clinical, Swing Out Head is agreed at quotation stage. Contact us with the rotors you need, the quantity and the delivery location in India or abroad.
To get a quotation for the Centrifuge, Clinical, Swing Out Head with any extra rotors, use our contact page or the enquiry cart.
Last updated: 24 September 2026