Air Sterilisation Unit (Product Code: SLE/SAH/37) is a compact, mobile UV-C air steriliser used to treat the air inside enclosed rooms such as classrooms, staff rooms, waiting areas and offices where many people gather. Five UV-C tubes inside the unit treat up to 800 m³ of air per hour, sized for a room of about 80 m³, and it runs from a standard 220-240 V supply on smooth castors. It is supplied by Jain Scientific Equipments Pvt Ltd (ScienceLab), Ambala, India.
| Parameter | Detail |
|---|---|
| Operating principle | Air drawn in through side inlets, exposed to UV-C radiation, then returned to the room through the front outlet by an internal fan |
| Number of UV-C tubes | 5 per unit |
| Air capacity | Up to 800 m³/hr per unit (technical data lists ≥800 m³/hr) |
| Applicable room size | 80 m³ per unit; multiple units can be combined for larger spaces |
| O3 concentration during dynamic sterilisation | ≤0.1 mg/m³ |
| Sound level | ≤55 dB |
| Size (H x W x D) | 830 x 425 x 300 mm |
| Weight | Approximately 25 kg |
| Power supply | AC 220-240 V, 50/60 Hz; standard 3-pin plug; simple on/off switch |
| Power consumption | ≤250 W |
| Working temperature | -10°C to 40°C |
| Working humidity | ≤80% |
| Atmospheric pressure | 60 kPa to 106 kPa |
| Lamp maintenance | UV lamps require replacing every 5000 hours |
| Mobility | Smooth castors; sized to pass through doorways |
| Caution | Use with caution in a potentially explosive atmosphere |
| Product code | SLE/SAH/37 |
| Supplied by | Jain Scientific Equipments Pvt Ltd (ScienceLab), Ambala, India |
UV-C light has long been used to kill bacteria and viruses; this unit applies it to room air inside a closed housing, so the treatment happens within the cabinet while people carry on working nearby. It is designed to stand beside staff, students or patients, or in spots where people crowd together, such as a classroom during lessons, an exam hall, a staff room or a reception queue.
Wheel the unit into position, plug it in and switch it on; there are no settings to get wrong, so little training is needed. Match the number of units to room volume at about 80 m³ each, keep inlets and the outlet clear of curtains and furniture, and log running hours so the UV lamps are replaced every 5000 hours. Do not place it near solvent stores or other potentially explosive atmospheres in a laboratory.
The Air Sterilisation Unit is sourced and supplied by Jain Scientific Equipments Private Limited, the company that trades as ScienceLab. Alongside laboratory and hygiene products, the company supplies equipment of this kind to schools, colleges, offices and institutions that want to add air treatment to their hygiene measures. Visit the company profile for more about us.
Air treatment is one part of a wider hygiene routine; these products cover surfaces and hands:
Browse all Water, Sanitation & Hygiene Supplies.
How large a room can one Air Sterilisation Unit treat?
One Air Sterilisation Unit is rated for an applicable room size of 80 m³ and treats up to 800 m³ of air per hour. For larger rooms or halls, several units can be combined and spaced around the area.
How does the Air Sterilisation Unit work?
The Air Sterilisation Unit draws room air in through side inlets, exposes it to UV-C radiation from five internal tubes, and an internal fan then returns the treated air to the room through the front outlet.
How often do the UV lamps need replacing?
The UV lamps in the Air Sterilisation Unit need replacing every 5000 hours of operation. Keep a simple log of running hours and contact us in advance if you would like replacement tubes included in a quotation.
How noisy is the Air Sterilisation Unit, and does it produce ozone?
The Air Sterilisation Unit has a sound level of 55 dB or less, and its technical data gives an ozone (O3) concentration of 0.1 mg/m³ or less in the air during dynamic sterilisation.
What power supply does it need?
The Air Sterilisation Unit runs on AC 220-240 V, 50/60 Hz through a standard 3-pin plug, with power consumption of 250 W or less. A single on/off switch controls it, so there is little risk of incorrect operation.
Where should the unit not be used?
Caution is needed when running the Air Sterilisation Unit in a potentially explosive atmosphere, so keep it away from flammable solvent stores. It is designed for working temperatures of -10°C to 40°C and humidity up to 80%.
Who supplies the Air Sterilisation Unit?
The Air Sterilisation Unit is supplied by Jain Scientific Equipments Pvt Ltd (ScienceLab), Ambala, India, to schools, colleges, offices, institutions and distributors in India and international markets. Share your room sizes through the contact page for a quotation.
Send the number of units, room sizes and delivery location for the Air Sterilisation Unit through our contact page, or add it to the enquiry cart, and we will prepare a quotation.
Last updated: 24 September 2026